Transcatheter Closure of Atrial Septal Defects in Children, Middle-Aged Adults, and Older Adults: Failure Rates, Early Complications; and Balloon Sizing Effects. (19th June 2012)
- Record Type:
- Journal Article
- Title:
- Transcatheter Closure of Atrial Septal Defects in Children, Middle-Aged Adults, and Older Adults: Failure Rates, Early Complications; and Balloon Sizing Effects. (19th June 2012)
- Main Title:
- Transcatheter Closure of Atrial Septal Defects in Children, Middle-Aged Adults, and Older Adults: Failure Rates, Early Complications; and Balloon Sizing Effects
- Authors:
- Vijarnsorn, Chodchanok
Durongpisitkul, Kritvikrom
Chanthong, Prakul
Chungsomprasong, Paweena
Soongswang, Jarupim
Loahaprasitiporn, Duangmanee
Nana, Apichart - Other Names:
- Bialkowski Jacek Academic Editor.
- Abstract:
- Abstract : Objectives . To compare the failure ratio and inhospital complications across three age groups of patients and to investigate the effects of balloon sizing on the success and the device diameter. Methods . This retrospective review was of 665 patients who had been listed for transcatheter-based closure of ASD between 1999 and 2010. The patients were divided into three age groups: children (<18 years; n = 183 ), adults (18–50 years; n = 337 ), and older adults (>50 years; n = 145 ). Procedural outcomes and early complications were reviewed. Use of balloon sizing was explored for its benefits. Results . Overall, failure of closure was 6.6% (n = 44 ). Use of balloon sizing tended to lead to a smaller device/defect ratio that was comparable to procedures without balloon sizing, though it did not predict the success rate (OR 1.4, 95% CI 0.7–2.3). Seven patients reported device embolization (1%). No mortalities were noted. In-hospital complications were 3.4%, with common complications, being vascular complications (1.4%) and cardiac arrhythmia (1.1%). No differences in failure rate or events were found among the three groups. Conclusion . Transcather closure of ASD is feasible and safe, regardless of the patient's age. A low rate of early complications was noted. Balloon sizing does not aggravate an oversizing of the device, but does not predict success.
- Is Part Of:
- Cardiology research and practice. Volume 2012(2012)
- Journal:
- Cardiology research and practice
- Issue:
- Volume 2012(2012)
- Issue Display:
- Volume 2012, Issue 2012 (2012)
- Year:
- 2012
- Volume:
- 2012
- Issue:
- 2012
- Issue Sort Value:
- 2012-2012-2012-0000
- Page Start:
- Page End:
- Publication Date:
- 2012-06-19
- Subjects:
- Cardiology -- Research -- Periodicals
Cardiology -- Periodicals
Cardiology
Cardiology
Cardiology -- Research
Electronic journals
Periodicals
Periodicals
616.12 - Journal URLs:
- http://bibpurl.oclc.org/web/46479 ↗
http://www.sage-hindawi.com/journals/crp/ ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/994/ ↗ - DOI:
- 10.1155/2012/584236 ↗
- Languages:
- English
- ISSNs:
- 2090-8016
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 16915.xml