Repeatability and Reproducibility of Measurements Using a NT-530P Noncontact Tono/Pachymeter and Correlation of Central Corneal Thickness with Intraocular Pressure. (3rd October 2013)
- Record Type:
- Journal Article
- Title:
- Repeatability and Reproducibility of Measurements Using a NT-530P Noncontact Tono/Pachymeter and Correlation of Central Corneal Thickness with Intraocular Pressure. (3rd October 2013)
- Main Title:
- Repeatability and Reproducibility of Measurements Using a NT-530P Noncontact Tono/Pachymeter and Correlation of Central Corneal Thickness with Intraocular Pressure
- Authors:
- Fujimura, Fusako
Kamiya, Kazutaka
Fujiwara, Kazuko
Shoji, Nobuyuki
Shimizu, Kimiya - Other Names:
- Kubota Toshiaki Academic Editor.
- Abstract:
- Abstract : Purpose . To investigate the repeatability and reproducibility of intraocular pressure (IOP) and central corneal thickness (CCT) measurements using a noncontact tono/pachymeter (NT-530P) and to assess the correlation of CCT with IOP. Methods . Forty-six eyes of healthy volunteers were measured by two examiners. Three consecutive measurements per eye were performed. Repeatability was assessed using the coefficient of variation, and reproducibility was assessed using Bland-Altman plots. Linear correlations were used to determine agreement between CCT and noncorrected IOP and CCT and corrected IOP, which was calculated using a formula built into the NT-530P. Results . The coefficient of variation for IOP was 6.4% and for CCT was 0.4%. The 95% limits of agreement between examiners were − 0.17 ± 1.42 mmHg (range: − 2.95 to 2.61 mmHg) for IOP, − 0.93 ± 4.37 μ m (range: − 9.50 to 7.64 μ m) for CCT. The corrected IOP was significantly higher than the noncorrected IOP (P = 0.010.3 ). The noncorrected IOP significantly correlated with CCT (r = − 0.4883, P = 0.0006 ). The corrected IOP showed no significant correlation with CCT (r = − 0.0285, P = 0.8509 ). Conclusions . NT-530P offered repeatability and reproducibility in both IOP and CCT measurements. The corrected IOP calculated using the NT-530P was independent of the CCT, suggesting that this IOP may be less influenced by the central corneal thickness.
- Is Part Of:
- BioMed research international. Volume 2013(2013)
- Journal:
- BioMed research international
- Issue:
- Volume 2013(2013)
- Issue Display:
- Volume 2013, Issue 2013 (2013)
- Year:
- 2013
- Volume:
- 2013
- Issue:
- 2013
- Issue Sort Value:
- 2013-2013-2013-0000
- Page Start:
- Page End:
- Publication Date:
- 2013-10-03
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2013/370592 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 16911.xml