X-ray spectra and gamma factors from 70 to 120 kV X-ray tube voltages. (July 2021)
- Record Type:
- Journal Article
- Title:
- X-ray spectra and gamma factors from 70 to 120 kV X-ray tube voltages. (July 2021)
- Main Title:
- X-ray spectra and gamma factors from 70 to 120 kV X-ray tube voltages
- Authors:
- Campillo-Rivera, Guillermo Eduardo
Torres-Cortes, Carina Oliva
Vazquez-Bañuelos, Joel
Garcia-Reyna, Mayra Guadalupe
Marquez-Mata, Claudia Angelica
Vasquez-Arteaga, Marcial
Vega-Carrillo, Hector Rene - Abstract:
- Abstract: The energy distribution of photons (spectrum) produced in X-ray generators, or X-ray tubes, depends on current, voltage and the target/filter combination; in turn, the dose depends on the spectrum. During the X-ray tube operation, the dose is due the direct beam or useful beam, the leaking out from the X-ray unit, and those photons scattered by the patient. The dose rate must be reduced to allowable limits using a shielding. In the shielding design an important parameter is the dose normalized to the current and the time, that in this work we named Gamma factor, as the factor used for gamma-ray sources. In this work analog Monte Carlo methods were used to calculate the photon spectra and the Gamma factors for air-Kerma and the Ambient dose equivalent for 70, 80, 90, 100 and 120 kV X-ray tubes having tungsten target and aluminum filter. The mean energies of photon spectra were calculated and the conversion coefficients for H*(10) and Ka per unit fluence were calculated and compared with the coefficients for monoenergetic photons. The glass enclosure and the filter eliminate the low-energy photons; calculated spectra show the continuous X-ray distribution due to Bremsstrahlung and the discrete distribution, due to characteristics X-rays. Photon fluences and doses depend on the X-ray unit voltage. Both gamma factors are similar to values recommended in norms while the fluence-to-dose (Ka and H*(10)) conversion coefficients in function of the mean energy are largerAbstract: The energy distribution of photons (spectrum) produced in X-ray generators, or X-ray tubes, depends on current, voltage and the target/filter combination; in turn, the dose depends on the spectrum. During the X-ray tube operation, the dose is due the direct beam or useful beam, the leaking out from the X-ray unit, and those photons scattered by the patient. The dose rate must be reduced to allowable limits using a shielding. In the shielding design an important parameter is the dose normalized to the current and the time, that in this work we named Gamma factor, as the factor used for gamma-ray sources. In this work analog Monte Carlo methods were used to calculate the photon spectra and the Gamma factors for air-Kerma and the Ambient dose equivalent for 70, 80, 90, 100 and 120 kV X-ray tubes having tungsten target and aluminum filter. The mean energies of photon spectra were calculated and the conversion coefficients for H*(10) and Ka per unit fluence were calculated and compared with the coefficients for monoenergetic photons. The glass enclosure and the filter eliminate the low-energy photons; calculated spectra show the continuous X-ray distribution due to Bremsstrahlung and the discrete distribution, due to characteristics X-rays. Photon fluences and doses depend on the X-ray unit voltage. Both gamma factors are similar to values recommended in norms while the fluence-to-dose (Ka and H*(10)) conversion coefficients in function of the mean energy are larger than the fluence-to-dose conversion coefficients for monoenergetic photons. Highlights: A model of X-ray tube with W-target and Al-filter was built. The X-ray spectra produced by 70–120 kV x-ray tubes were estimated. The Ka and the H*(10) Gamma factors were calculated. The fluence-to-Ka and fluence-to-H*(10) conversion coefficients were calculated. … (more)
- Is Part Of:
- Radiation physics and chemistry. Volume 184(2021)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 184(2021)
- Issue Display:
- Volume 184, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 184
- Issue:
- 2021
- Issue Sort Value:
- 2021-0184-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-07
- Subjects:
- X-rays -- Spectra -- Air kerma -- Ambient dose equivalent -- Gamma factors -- Monte Carlo
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2021.109437 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16841.xml