A microfluidic-integrated lateral flow recombinase polymerase amplification (MI-IF-RPA) assay for rapid COVID-19 detection. Issue 10 (8th April 2021)
- Record Type:
- Journal Article
- Title:
- A microfluidic-integrated lateral flow recombinase polymerase amplification (MI-IF-RPA) assay for rapid COVID-19 detection. Issue 10 (8th April 2021)
- Main Title:
- A microfluidic-integrated lateral flow recombinase polymerase amplification (MI-IF-RPA) assay for rapid COVID-19 detection
- Authors:
- Liu, Dan
Shen, Haicong
Zhang, Yuqian
Shen, Danyu
Zhu, Mingyang
Song, Yanling
Zhu, Zhi
Yang, Chaoyong - Abstract:
- Abstract : A simple microfluidic-integrated lateral flow recombinase polymerase amplification (MI-IF-RPA) assay was developed for rapid COVID-19 detection. Abstract : The COVID-19 pandemic, caused by SARS-CoV-2, currently poses an urgent global medical crisis for which there remains a lack of affordable point-of-care testing (POCT). In particular, resource-limited areas need simple and easily disseminated testing solutions to manage the outbreak. In this work, a microfluidic-integrated lateral flow recombinase polymerase amplification (MI-IF-RPA) assay was developed for rapid and sensitive detection of SARS-CoV-2, which integrates the reverse transcription recombinase polymerase amplification (RT-RPA) and a universal lateral flow (LF) dipstick detection system into a single microfluidic chip. The single-chamber RT-RPA reaction components are mixed with running buffer, and then delivered to the LF detection strips for biotin- and FAM-labelled amplified analyte sequences, which can provide easily interpreted positive or negative results. Testing requires only a simple nucleic acid extraction and loading, then incubation to obtain results, approximately 30 minutes in total. SARS-CoV-2 armored RNA particles were used to validate the MI-IF-RPA system, which showed a limit of detection of 1 copy per μL, or 30 copies per sample. Chip performance was further evaluated using clinically diagnosed cases of COVID-19 and revealed a sensitivity of 97% and specificity of 100%, highlyAbstract : A simple microfluidic-integrated lateral flow recombinase polymerase amplification (MI-IF-RPA) assay was developed for rapid COVID-19 detection. Abstract : The COVID-19 pandemic, caused by SARS-CoV-2, currently poses an urgent global medical crisis for which there remains a lack of affordable point-of-care testing (POCT). In particular, resource-limited areas need simple and easily disseminated testing solutions to manage the outbreak. In this work, a microfluidic-integrated lateral flow recombinase polymerase amplification (MI-IF-RPA) assay was developed for rapid and sensitive detection of SARS-CoV-2, which integrates the reverse transcription recombinase polymerase amplification (RT-RPA) and a universal lateral flow (LF) dipstick detection system into a single microfluidic chip. The single-chamber RT-RPA reaction components are mixed with running buffer, and then delivered to the LF detection strips for biotin- and FAM-labelled amplified analyte sequences, which can provide easily interpreted positive or negative results. Testing requires only a simple nucleic acid extraction and loading, then incubation to obtain results, approximately 30 minutes in total. SARS-CoV-2 armored RNA particles were used to validate the MI-IF-RPA system, which showed a limit of detection of 1 copy per μL, or 30 copies per sample. Chip performance was further evaluated using clinically diagnosed cases of COVID-19 and revealed a sensitivity of 97% and specificity of 100%, highly comparable to current reverse transcription-polymerase chain reaction (RT-PCR)-based diagnostic assays. This MI-IF-RPA assay is portable and comprises affordable materials, enabling mass production and decreased risk of contamination. Without the need for specialized instrumentation and training, MI-IF-RPA assay can be used as a complement to RT-PCR for low-cost COVID-19 screening in resource-limited areas. … (more)
- Is Part Of:
- Lab on a chip. Volume 21:Issue 10(2021)
- Journal:
- Lab on a chip
- Issue:
- Volume 21:Issue 10(2021)
- Issue Display:
- Volume 21, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 21
- Issue:
- 10
- Issue Sort Value:
- 2021-0021-0010-0000
- Page Start:
- 2019
- Page End:
- 2026
- Publication Date:
- 2021-04-08
- Subjects:
- Miniature electronic equipment -- Periodicals
Combinatorial chemistry -- Periodicals
Biotechnology -- Periodicals
543.0813 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/lc#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d0lc01222j ↗
- Languages:
- English
- ISSNs:
- 1473-0197
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5137.730000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16856.xml