Lactose Malabsorption Testing in Daily Clinical Practice: A Critical Retrospective Analysis and Comparison of the Hydrogen/Methane Breath Test and Genetic Test (C/T-13910 Polymorphism) Results. (16th April 2014)
- Record Type:
- Journal Article
- Title:
- Lactose Malabsorption Testing in Daily Clinical Practice: A Critical Retrospective Analysis and Comparison of the Hydrogen/Methane Breath Test and Genetic Test (C/T-13910 Polymorphism) Results. (16th April 2014)
- Main Title:
- Lactose Malabsorption Testing in Daily Clinical Practice: A Critical Retrospective Analysis and Comparison of the Hydrogen/Methane Breath Test and Genetic Test (C/T-13910 Polymorphism) Results
- Authors:
- Enko, Dietmar
Rezanka, Erwin
Stolba, Robert
Halwachs-Baumann, Gabriele - Other Names:
- Whorwell Peter James Academic Editor.
- Abstract:
- Abstract : The aim of this study was to establish a retrospective evaluation and comparison of the hydrogen/methane (H2 /CH4 ) breath test and genetic test (C/T−13910 polymorphism) results in lactose malabsorption testing. In total 263 consecutive patients with suspected lactose malabsorption were included in this study. They underwent the H2 /CH4 breath test following the ingestion of 50 g lactose and were tested for the C/T−13910 polymorphism. In total 51 patients (19.4%) had a C/C−13910 genotype, indicating primary lactose malabsorption. Only 19 patients (7.2%) also had a positive H2 /CH4 breath test. All in all 136 patients (51.69%) had a C/T−13910 and 76 patients (28.91%) a T/T−13910 genotype, indicating lactase persistence. Four patients (1.5%) with the C/T−13910 genotype and one patient (0.4%) with the T/T−13910 genotype had a positive H2 /CH4 breath test result, indicating secondary lactose malabsorption. Cohen's Kappa measuring agreement between the two methods was 0.44. Twenty patients (7.6%) with a positive H2 /CH4 peak within 60 minutes after lactose ingestion were classified as patients with lactose-dependent small intestinal bacterial overgrowth (SIBO). In conclusion, only moderate agreement between the breath test and the genetic test was shown. Secondary lactose malabsorption as well as preanalytical limitations of the combined H2 /CH4 breath test procedure can cause discrepant results. This trial is registered with K-42-13.
- Is Part Of:
- Gastroenterology research and practice. Volume 2014(2014)
- Journal:
- Gastroenterology research and practice
- Issue:
- Volume 2014(2014)
- Issue Display:
- Volume 2014, Issue 2014 (2014)
- Year:
- 2014
- Volume:
- 2014
- Issue:
- 2014
- Issue Sort Value:
- 2014-2014-2014-0000
- Page Start:
- Page End:
- Publication Date:
- 2014-04-16
- Subjects:
- Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
616.33005 - Journal URLs:
- https://www.hindawi.com/journals/grp/ ↗
- DOI:
- 10.1155/2014/464382 ↗
- Languages:
- English
- ISSNs:
- 1687-6121
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 16853.xml