Skin‐Interfaced Microfluidic Systems that Combine Hard and Soft Materials for Demanding Applications in Sweat Capture and Analysis. Issue 4 (29th September 2020)
- Record Type:
- Journal Article
- Title:
- Skin‐Interfaced Microfluidic Systems that Combine Hard and Soft Materials for Demanding Applications in Sweat Capture and Analysis. Issue 4 (29th September 2020)
- Main Title:
- Skin‐Interfaced Microfluidic Systems that Combine Hard and Soft Materials for Demanding Applications in Sweat Capture and Analysis
- Authors:
- Choi, Jungil
Chen, Shulin
Deng, Yujun
Xue, Yeguang
Reeder, Jonathan T.
Franklin, Daniel
Oh, Yong Suk
Model, Jeffrey B.
Aranyosi, Alexander J.
Lee, Stephen P.
Ghaffari, Roozbeh
Huang, Yonggang
Rogers, John A. - Other Names:
- Xia Younan guestEditor.
- Abstract:
- Abstract: Eccrine sweat contains a rich blend of electrolytes, metabolites, proteins, metal ions, and other biomarkers. Changes in the concentrations of these chemical species can indicate alterations in hydration status and they can also reflect health conditions such as cystic fibrosis, schizophrenia, and depression. Recent advances in soft, skin‐interfaced microfluidic systems enable real‐time measurement of local sweat loss and sweat biomarker concentrations, with a wide range of applications in healthcare. Uses in certain contexts involve, however, physical impacts on the body that can dynamically deform these platforms, with adverse effects on measurement reliability. The work presented here overcomes this limitation through the use of microfluidic structures constructed in relatively high modulus polymers, and designed in geometries that offer soft, system level mechanics when embedded low modulus elastomers. Analytical models and finite element analysis quantitatively define the relevant mechanics of these systems, and serve as the basis for layouts optimized to allow robust operation in demanding, rugged scenarios such as those encountered in football, while preserving mechanical stretchability for comfortable, water‐tight bonding to the skin. Benchtop testing and on‐body field studies of measurements of sweat loss and chloride concentration under imposed mechanical stresses and impacts demonstrate the key features of these platforms. Abstract : Skin‐interfacedAbstract: Eccrine sweat contains a rich blend of electrolytes, metabolites, proteins, metal ions, and other biomarkers. Changes in the concentrations of these chemical species can indicate alterations in hydration status and they can also reflect health conditions such as cystic fibrosis, schizophrenia, and depression. Recent advances in soft, skin‐interfaced microfluidic systems enable real‐time measurement of local sweat loss and sweat biomarker concentrations, with a wide range of applications in healthcare. Uses in certain contexts involve, however, physical impacts on the body that can dynamically deform these platforms, with adverse effects on measurement reliability. The work presented here overcomes this limitation through the use of microfluidic structures constructed in relatively high modulus polymers, and designed in geometries that offer soft, system level mechanics when embedded low modulus elastomers. Analytical models and finite element analysis quantitatively define the relevant mechanics of these systems, and serve as the basis for layouts optimized to allow robust operation in demanding, rugged scenarios such as those encountered in football, while preserving mechanical stretchability for comfortable, water‐tight bonding to the skin. Benchtop testing and on‐body field studies of measurements of sweat loss and chloride concentration under imposed mechanical stresses and impacts demonstrate the key features of these platforms. Abstract : Skin‐interfaced microfluidic systems that combine hard and soft materials allow robust operation in demanding, rugged scenarios such as those encountered in contact sports, while preserving mechanical stretchability for comfortable, water‐tight bonding to the skin through the use of microfluidic structures constructed in relatively high modulus polymers, and designed in geometries that offer soft, system level mechanics. … (more)
- Is Part Of:
- Advanced healthcare materials. Volume 10:Issue 4(2021)
- Journal:
- Advanced healthcare materials
- Issue:
- Volume 10:Issue 4(2021)
- Issue Display:
- Volume 10, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 10
- Issue:
- 4
- Issue Sort Value:
- 2021-0010-0004-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-09-29
- Subjects:
- finite element analysis -- material engineering -- microfludic devices -- sweat analysis -- wearable devices
Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2192-2659 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/adhm.202000722 ↗
- Languages:
- English
- ISSNs:
- 2192-2640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0696.854650
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: