CT‐Angiography to predict outcome after indirect mitral annuloplasty in patients with functional mitral regurgitation. Issue 3 (30th June 2020)
- Record Type:
- Journal Article
- Title:
- CT‐Angiography to predict outcome after indirect mitral annuloplasty in patients with functional mitral regurgitation. Issue 3 (30th June 2020)
- Main Title:
- CT‐Angiography to predict outcome after indirect mitral annuloplasty in patients with functional mitral regurgitation
- Authors:
- Rottländer, Dennis
Ballof, Jan
Gödde, Miriel
Degen, Hubertus
Ögütcü, Alev
Alektorov, Kirill
Chatrou, Martijn
Heintzen, Matthias P.
Haude, Michael - Abstract:
- Abstract: Objectives: Coronary sinus (CS) based mitral annuloplasty using the Carillon device is effective in reducing functional mitral valve regurgitation (FMR). However, this positive effect might be dependent on the relation between CS and the mitral annulus. Background: Computed tomography (CT) assessment prior to mitral valve interventions is an emerging technique to optimize patient selection. Methods: In a retrospective analysis 30 patients underwent Carillon device implantation and received CT‐angiography prior to CS based percutaneous mitral valve repair. Patients were assigned to responders or non‐responders according to the 3‐month transthoracic echocardiographic follow‐up including quantitative mitral valve regurgitation assessment. A prototype software for CS reconstruction was used to assess distance and angle of both CS and mitral annulus planes. Results: Comparison of the distance and angle of the CS plane and the mitral valve annulus plane showed a significant shorter distance and lower angle in the responder group implicating an impact on procedure success. Our results suggest a CS plane and MV annulus plane with a favorably distance of <7.8 mm and an optimal angle of <14.2° could be considered favorably for mitral annuloplasty using a Carillon device. Conclusions: Distance and angle of mitral annulus and CS planes determined by three‐dimensional reconstructions of CT‐angiography might predict a reduction in echocardiographic FMR using Carillon MitralAbstract: Objectives: Coronary sinus (CS) based mitral annuloplasty using the Carillon device is effective in reducing functional mitral valve regurgitation (FMR). However, this positive effect might be dependent on the relation between CS and the mitral annulus. Background: Computed tomography (CT) assessment prior to mitral valve interventions is an emerging technique to optimize patient selection. Methods: In a retrospective analysis 30 patients underwent Carillon device implantation and received CT‐angiography prior to CS based percutaneous mitral valve repair. Patients were assigned to responders or non‐responders according to the 3‐month transthoracic echocardiographic follow‐up including quantitative mitral valve regurgitation assessment. A prototype software for CS reconstruction was used to assess distance and angle of both CS and mitral annulus planes. Results: Comparison of the distance and angle of the CS plane and the mitral valve annulus plane showed a significant shorter distance and lower angle in the responder group implicating an impact on procedure success. Our results suggest a CS plane and MV annulus plane with a favorably distance of <7.8 mm and an optimal angle of <14.2° could be considered favorably for mitral annuloplasty using a Carillon device. Conclusions: Distance and angle of mitral annulus and CS planes determined by three‐dimensional reconstructions of CT‐angiography might predict a reduction in echocardiographic FMR using Carillon Mitral Contour System. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 97:Issue 3(2021)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 97:Issue 3(2021)
- Issue Display:
- Volume 97, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 97
- Issue:
- 3
- Issue Sort Value:
- 2021-0097-0003-0000
- Page Start:
- 495
- Page End:
- 502
- Publication Date:
- 2020-06-30
- Subjects:
- computer tomography -- coronary sinus -- echocardiography -- mitral valve
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.29107 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16856.xml