The Role of CT-Based Attenuation Correction and Collimator Blurring Correction in Striatal Spect Quantification. (6th April 2011)
- Record Type:
- Journal Article
- Title:
- The Role of CT-Based Attenuation Correction and Collimator Blurring Correction in Striatal Spect Quantification. (6th April 2011)
- Main Title:
- The Role of CT-Based Attenuation Correction and Collimator Blurring Correction in Striatal Spect Quantification
- Authors:
- Warwick, J. M.
Rubow, S.
du Toit, M.
Beetge, E.
Carey, P.
Dupont, P. - Other Names:
- El Fakhri Georges Academic Editor.
- Abstract:
- Abstract : Purpose . Striatal single photon emission computed tomography (SPECT) imaging of the dopaminergic system is becoming increasingly used for clinical and research studies. The question about the value of nonuniform attenuation correction has become more relevant with the increasing availability of hybrid SPECT-CT scanners. In this study, the value of nonuniform attenuation correction and correction for collimator blurring were determined using both phantom data and patient data. Methods . SPECT imaging was performed using 7 anthropomorphic phantom measurements, and 14 patient studies using [I-123]-FP-CIT (DATSCAN). SPECT reconstruction was performed using uniform and nonuniform attenuation correction and collimator blurring corrections. Recovery values (phantom data) or average-specific uptake ratios (patient data) for the different reconstructions were compared at similar noise levels. Results . For the phantom data, improved recovery was found with nonuniform attenuation correction and collimator blurring corrections, with further improvement when performed together. However, for patient data the highest average specific uptake ratio was obtained using collimator blurring correction without nonuniform attenuation correction, probably due to subtle SPECT-CT misregistration. Conclusions . This study suggests that an optimal brain SPECT reconstruction (in terms of the lowest bias) in patients would include a correction for collimator blurring and uniform attenuationAbstract : Purpose . Striatal single photon emission computed tomography (SPECT) imaging of the dopaminergic system is becoming increasingly used for clinical and research studies. The question about the value of nonuniform attenuation correction has become more relevant with the increasing availability of hybrid SPECT-CT scanners. In this study, the value of nonuniform attenuation correction and correction for collimator blurring were determined using both phantom data and patient data. Methods . SPECT imaging was performed using 7 anthropomorphic phantom measurements, and 14 patient studies using [I-123]-FP-CIT (DATSCAN). SPECT reconstruction was performed using uniform and nonuniform attenuation correction and collimator blurring corrections. Recovery values (phantom data) or average-specific uptake ratios (patient data) for the different reconstructions were compared at similar noise levels. Results . For the phantom data, improved recovery was found with nonuniform attenuation correction and collimator blurring corrections, with further improvement when performed together. However, for patient data the highest average specific uptake ratio was obtained using collimator blurring correction without nonuniform attenuation correction, probably due to subtle SPECT-CT misregistration. Conclusions . This study suggests that an optimal brain SPECT reconstruction (in terms of the lowest bias) in patients would include a correction for collimator blurring and uniform attenuation correction. … (more)
- Is Part Of:
- International journal of molecular imaging. Volume 2011(2011)
- Journal:
- International journal of molecular imaging
- Issue:
- Volume 2011(2011)
- Issue Display:
- Volume 2011, Issue 2011 (2011)
- Year:
- 2011
- Volume:
- 2011
- Issue:
- 2011
- Issue Sort Value:
- 2011-2011-2011-0000
- Page Start:
- Page End:
- Publication Date:
- 2011-04-06
- Subjects:
- Molecular diagnosis -- Periodicals
Molecular probes -- Diagnostic use -- Periodicals
Diagnostic imaging -- Periodicals
Molecular Imaging
Diagnostic imaging
Molecular diagnosis
Electronic journals
Periodicals
Periodicals
616.0757 - Journal URLs:
- http://www.hindawi.com/journals/ijmi/ ↗
http://bibpurl.oclc.org/web/46487 ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1490/ ↗ - DOI:
- 10.1155/2011/195037 ↗
- Languages:
- English
- ISSNs:
- 2090-1712
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 16813.xml