AAPM Task Group 264: The safe clinical implementation of MLC tracking in radiotherapy. Issue 5 (23rd March 2021)
- Record Type:
- Journal Article
- Title:
- AAPM Task Group 264: The safe clinical implementation of MLC tracking in radiotherapy. Issue 5 (23rd March 2021)
- Main Title:
- AAPM Task Group 264: The safe clinical implementation of MLC tracking in radiotherapy
- Authors:
- Keall, Paul J.
Sawant, Amit
Berbeco, Ross I.
Booth, Jeremy T.
Cho, Byungchul
Cerviño, Laura I.
Cirino, Eileen
Dieterich, Sonja
Fast, Martin F.
Greer, Peter B.
Munck af Rosenschöld, Per
Parikh, Parag J.
Poulsen, Per Rugaard
Santanam, Lakshmi
Sherouse, George W.
Shi, Jie
Stathakis, Sotirios - Abstract:
- Abstract : The era of real‐time radiotherapy is upon us. Robotic and gimbaled linac tracking are clinically established technologies with the clinical realization of couch tracking in development. Multileaf collimators (MLCs) are a standard equipment for most cancer radiotherapy systems, and therefore MLC tracking is a potentially widely available technology. MLC tracking has been the subject of theoretical and experimental research for decades and was first implemented for patient treatments in 2013. The AAPM Task Group 264 Safe Clinical Implementation of MLC Tracking in Radiotherapy Report was charged to proactively provide the broader radiation oncology community with (a) clinical implementation guidelines including hardware, software, and clinical indications for use, (b) commissioning and quality assurance recommendations based on early user experience, as well as guidelines on Failure Mode and Effects Analysis, and (c) a discussion of potential future developments. The deliverables from this report include: an explanation of MLC tracking and its historical development; terms and definitions relevant to MLC tracking; the clinical benefit of, clinical experience with and clinical implementation guidelines for MLC tracking; quality assurance guidelines, including example quality assurance worksheets; a clinical decision pathway, future outlook and overall recommendations. Abstract :
- Is Part Of:
- Medical physics. Volume 48:Issue 5(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 5(2021)
- Issue Display:
- Volume 48, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 5
- Issue Sort Value:
- 2021-0048-0005-0000
- Page Start:
- e44
- Page End:
- e64
- Publication Date:
- 2021-03-23
- Subjects:
- Clinical implementation -- Multileaf collimator tracking -- Treatment beam adaptation
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14625 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16820.xml