Thermal degradation characteristics, kinetics and thermodynamics of micron-sized PMMA in oxygenous atmosphere using thermogravimetry and deconvolution method based on Gauss function. (July 2021)
- Record Type:
- Journal Article
- Title:
- Thermal degradation characteristics, kinetics and thermodynamics of micron-sized PMMA in oxygenous atmosphere using thermogravimetry and deconvolution method based on Gauss function. (July 2021)
- Main Title:
- Thermal degradation characteristics, kinetics and thermodynamics of micron-sized PMMA in oxygenous atmosphere using thermogravimetry and deconvolution method based on Gauss function
- Authors:
- Chen, Ruiyu
Pan, Renming
Li, Quanwei - Abstract:
- Abstract: Micron-sized poly (methyl methacrylate) (PMMA) with high flammability is widely applied in industries, constructions and transportations. Study on the thermal degradation behaviors of micron-sized PMMA in oxygenous atmosphere, which receives scarce attention to date, can provide valuable guidance for the prevention and mitigation of injuries and damages arising from the micron-sized PMMA dust explosions and fires. In the present study, the thermal degradation characteristics of micron-sized PMMA in air were investigated by thermogravimetry. Deconvolution method using Gauss function coupled with model-free and model-fitting methods was employed to conduct the kinetic modeling. The values of thermodynamic parameters ( ΔH, ΔG and ΔS ) were estimated. The results indicated that one peak and one shoulder occurred in the mass loss rate (MLR) variations of the micron-sized PMMA degradation in air. The values of MLR at peak and shoulder both decreased with heating rate. Besides, the average value of the MLR varied little with heating rate. The values of MLR at the peak and the average MLR of micron-sized PMMA degradation in air were both less than those of the traditional-sized PMMA degradation in air. The calculated kinetic parameters can be used to well predict the thermal degradation behaviors of micron-sized PMMA in air. Additionally, the micron-sized PMMA in air was easier to decompose than the traditional-sized PMMA in air. Non-spontaneous reactions were involved inAbstract: Micron-sized poly (methyl methacrylate) (PMMA) with high flammability is widely applied in industries, constructions and transportations. Study on the thermal degradation behaviors of micron-sized PMMA in oxygenous atmosphere, which receives scarce attention to date, can provide valuable guidance for the prevention and mitigation of injuries and damages arising from the micron-sized PMMA dust explosions and fires. In the present study, the thermal degradation characteristics of micron-sized PMMA in air were investigated by thermogravimetry. Deconvolution method using Gauss function coupled with model-free and model-fitting methods was employed to conduct the kinetic modeling. The values of thermodynamic parameters ( ΔH, ΔG and ΔS ) were estimated. The results indicated that one peak and one shoulder occurred in the mass loss rate (MLR) variations of the micron-sized PMMA degradation in air. The values of MLR at peak and shoulder both decreased with heating rate. Besides, the average value of the MLR varied little with heating rate. The values of MLR at the peak and the average MLR of micron-sized PMMA degradation in air were both less than those of the traditional-sized PMMA degradation in air. The calculated kinetic parameters can be used to well predict the thermal degradation behaviors of micron-sized PMMA in air. Additionally, the micron-sized PMMA in air was easier to decompose than the traditional-sized PMMA in air. Non-spontaneous reactions were involved in the thermo-oxidative degradation of micron-sized PMMA. Besides, with the progressing of thermo-oxidative degradation, less energy was required and pyrolytic products with well-ordered structures may be generated. Highlights: The maximum value of mass loss rate decreases with heating rate. Micron-sized PMMA is easier to decompose than traditional-sized PMMA in air. Deconvolution method with Gauss function can well separate the overlapped peaks. Model-free and model-fitting methods are used for kinetic modeling. Predicted thermogravimetric data agree well with experimental ones. … (more)
- Is Part Of:
- Journal of loss prevention in the process industries. Volume 71(2021)
- Journal:
- Journal of loss prevention in the process industries
- Issue:
- Volume 71(2021)
- Issue Display:
- Volume 71, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 71
- Issue:
- 2021
- Issue Sort Value:
- 2021-0071-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-07
- Subjects:
- Thermo-oxidative degradation -- Micron-sized PMMA -- Thermogravimetry -- Kinetics -- Thermodynamics
Chemical industries -- Safety measures -- Periodicals
660.2804 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09504230/ ↗
http://www.journals.elsevier.com/journal-of-loss-prevention-in-the-process-industries/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jlp.2021.104488 ↗
- Languages:
- English
- ISSNs:
- 0950-4230
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.562000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16830.xml