Three-dimensional surface strain analyses of simulated defect and augmented spine segments: A biomechanical cadaveric study. (July 2021)
- Record Type:
- Journal Article
- Title:
- Three-dimensional surface strain analyses of simulated defect and augmented spine segments: A biomechanical cadaveric study. (July 2021)
- Main Title:
- Three-dimensional surface strain analyses of simulated defect and augmented spine segments: A biomechanical cadaveric study
- Authors:
- Rezaei, Asghar
Tilton, Maryam
Giambini, Hugo
Li, Yong
Hooke, Alexander
Miller II, Alan L.
Yaszemski, Michael J.
Lu, Lichun - Abstract:
- Abstract: While several studies have investigated fracture outcomes of intact vertebrae, fracture properties in metastatically-involved and augmented vertebrae are still far from understood. Consequently, this study was aimed to use 3D digital image correlation (3D-DIC) method to investigate the failure properties of spine segments with simulated metastatic lesions, segments augmented with poly(propylene fumarate) (PPF), and compare the outcomes with intact spines. To this end, biomechanical experiments accompanied by 3D-DIC were performed on spine segments consisting of three vertebrae and two intervertebral discs (IVDs) at loading rates of 0.083 mm/s, mimicking a physiological loading condition, and 200 mm/s, mimicking an impact-type loading condition such as a fall or an accident. Full-field surface strain analysis indicated PPF augmentation reduces the superior/inferior strain when compared with the defect specimens; Presence of a defect in the middle vertebra resulted in shear band fracture pattern. Failure of the superior endplates was confirmed in several defect specimens as the superior IVDs were protruding out of defects. The augmenting PPF showed lower superior/inferior surface strain values at the fast speed as compared to the slow speed. The results of our study showed a significant increase in the fracture force from slow to fast speeds (p = 0.0246). The significance of the study was to determine the fracture properties of normal, pathological, and augmentedAbstract: While several studies have investigated fracture outcomes of intact vertebrae, fracture properties in metastatically-involved and augmented vertebrae are still far from understood. Consequently, this study was aimed to use 3D digital image correlation (3D-DIC) method to investigate the failure properties of spine segments with simulated metastatic lesions, segments augmented with poly(propylene fumarate) (PPF), and compare the outcomes with intact spines. To this end, biomechanical experiments accompanied by 3D-DIC were performed on spine segments consisting of three vertebrae and two intervertebral discs (IVDs) at loading rates of 0.083 mm/s, mimicking a physiological loading condition, and 200 mm/s, mimicking an impact-type loading condition such as a fall or an accident. Full-field surface strain analysis indicated PPF augmentation reduces the superior/inferior strain when compared with the defect specimens; Presence of a defect in the middle vertebra resulted in shear band fracture pattern. Failure of the superior endplates was confirmed in several defect specimens as the superior IVDs were protruding out of defects. The augmenting PPF showed lower superior/inferior surface strain values at the fast speed as compared to the slow speed. The results of our study showed a significant increase in the fracture force from slow to fast speeds (p = 0.0246). The significance of the study was to determine the fracture properties of normal, pathological, and augmented spinal segments under physiologically-relevant loading conditions. Understanding failure properties associated with either defect (i.e., metastasis lesion) or augmented (i.e., post-treatment) spine segments could potentially provide new insights on the outcome prediction and treatment planning. Additionally, this study provides new knowledge on the effect of PPF augmentation in improving fracture properties, potentially decreasing the risk of fracture in osteoporotic and metastatic spines. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 119(2021)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 119(2021)
- Issue Display:
- Volume 119, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 119
- Issue:
- 2021
- Issue Sort Value:
- 2021-0119-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-07
- Subjects:
- Biomechanics of vertebral bodies -- Metastasis -- Mechanical testing -- Fracture outcomes -- Vertebral augmentation
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2021.104559 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16822.xml