Osseointegration evaluation of UHMWPE and PEEK-based scaffolds with BMP-2 using model of critical-size cranial defect in mice and push-out test. (July 2021)
- Record Type:
- Journal Article
- Title:
- Osseointegration evaluation of UHMWPE and PEEK-based scaffolds with BMP-2 using model of critical-size cranial defect in mice and push-out test. (July 2021)
- Main Title:
- Osseointegration evaluation of UHMWPE and PEEK-based scaffolds with BMP-2 using model of critical-size cranial defect in mice and push-out test
- Authors:
- Senatov, F.
Maksimkin, A.
Chubrik, A.
Kolesnikov, E.
Orlova, P.
Krivozubov, M.
Nikitin, K.
Gromov, A.
Karyagina, A. - Abstract:
- Abstract: It the present study the push-out mechanical test was adopted for mouse model of implantation in critical-size cranial defects to evaluate the effectiveness of implant-skull fusion. As implants, disks of porous ultra-high molecular weight polyethylene (UHMWPE) and polyetheretherketone (PEEK) with hydroxylapatite (HA) with and without loading of recombinant bone morphogenetic protein-2 (BMP-2) were used. Implantation results were evaluated using histology and micro-computed tomography (micro-CT). In the case of both UHMWPE/HA and PEEK/HA, BMP-2 loading resulted in a significant increase in the amount of bone tissue in the implantation area, especially at the edges of the defect, and an increase in the value of BV/TV (bone volume/tissue volume) during micro-CT. There was a high correlation of BV/TV values with the maximum load and elastic modulus measured during the puch-out test. The maximum load values showed good convergence within the groups and are comparable to the maximum load values obtained by other authors in the rat model of implantation in critical-size cranial defects. An adapted push-out test can be used to evaluate the quality of osseointegration of the implanted materials. Graphical abstract: Image 1 Highlights: Push-out test was adopted for a mouse model of critical-size cranial defects. High correlation was obtained between push-out tests, micro-CT and histological data. Porous UHMWPE/HA and PEEK/HA implants with rhBMP-2 provide bone tissueAbstract: It the present study the push-out mechanical test was adopted for mouse model of implantation in critical-size cranial defects to evaluate the effectiveness of implant-skull fusion. As implants, disks of porous ultra-high molecular weight polyethylene (UHMWPE) and polyetheretherketone (PEEK) with hydroxylapatite (HA) with and without loading of recombinant bone morphogenetic protein-2 (BMP-2) were used. Implantation results were evaluated using histology and micro-computed tomography (micro-CT). In the case of both UHMWPE/HA and PEEK/HA, BMP-2 loading resulted in a significant increase in the amount of bone tissue in the implantation area, especially at the edges of the defect, and an increase in the value of BV/TV (bone volume/tissue volume) during micro-CT. There was a high correlation of BV/TV values with the maximum load and elastic modulus measured during the puch-out test. The maximum load values showed good convergence within the groups and are comparable to the maximum load values obtained by other authors in the rat model of implantation in critical-size cranial defects. An adapted push-out test can be used to evaluate the quality of osseointegration of the implanted materials. Graphical abstract: Image 1 Highlights: Push-out test was adopted for a mouse model of critical-size cranial defects. High correlation was obtained between push-out tests, micro-CT and histological data. Porous UHMWPE/HA and PEEK/HA implants with rhBMP-2 provide bone tissue ingrowth. Quantitative study of implanted materials degree of integration was performed. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 119(2021)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 119(2021)
- Issue Display:
- Volume 119, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 119
- Issue:
- 2021
- Issue Sort Value:
- 2021-0119-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-07
- Subjects:
- Mechanical properties -- Push-out test -- Osseointegration -- UHMWPE -- PEEK -- BMP-2 -- Hydroxylapatite -- Scaffold -- Protein -- Microstructure
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2021.104477 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16821.xml