Effects of variable‐width jaw motion on beam characteristics for Radixact Synchrony®. Issue 5 (29th March 2021)
- Record Type:
- Journal Article
- Title:
- Effects of variable‐width jaw motion on beam characteristics for Radixact Synchrony®. Issue 5 (29th March 2021)
- Main Title:
- Effects of variable‐width jaw motion on beam characteristics for Radixact Synchrony®
- Authors:
- Ferris, William S.
Culberson, Wesley S.
Smilowitz, Jennifer B.
Bayouth, John E. - Abstract:
- Abstract: Purpose: Radixact Synchrony corrects for target motion during treatment by adjusting the jaw and MLC positions in real time. As the jaws move off axis, Synchrony attempts to adjust for a loss in output due to the un‐flattened 6 MV beam by increasing the jaw aperture width. The purpose of this work was to assess the impact of the variable‐width aperture on delivered dose using measurements and simulations. Methods: Longitudinal beam profile measurements were acquired using an Edge diode with static gantry. Jaw‐offset peak, width, and integral factors were calculated for profiles with the jaws in the extreme positions using both variable‐width (Synchrony) and fixed‐width apertures. Treatment plans with target motion and compensation were compared to planned doses to study the impact of the variable aperture on volumetric dose. Results: The jaw offset peak factor (JOPF) for the Synchrony jaw settings were 0.964 and 0.983 for the 1.0‐ and 2.5‐cm jaw settings, respectively. These values decreased to 0.925 and 0.982 for the fixed‐width settings, indicating that the peak value of the profile would decrease by 7.5% compared to centered if the aperture width was held constant. The IMRT dose distributions reveal similar results, where gamma pass rates are above tolerance for the Synchrony jaw settings but fall significantly for the fixed‐width 1‐cm jaws. Conclusions: The variable‐width behavior of Synchrony jaws provides a larger output correction for the 1‐cm jaw setting.Abstract: Purpose: Radixact Synchrony corrects for target motion during treatment by adjusting the jaw and MLC positions in real time. As the jaws move off axis, Synchrony attempts to adjust for a loss in output due to the un‐flattened 6 MV beam by increasing the jaw aperture width. The purpose of this work was to assess the impact of the variable‐width aperture on delivered dose using measurements and simulations. Methods: Longitudinal beam profile measurements were acquired using an Edge diode with static gantry. Jaw‐offset peak, width, and integral factors were calculated for profiles with the jaws in the extreme positions using both variable‐width (Synchrony) and fixed‐width apertures. Treatment plans with target motion and compensation were compared to planned doses to study the impact of the variable aperture on volumetric dose. Results: The jaw offset peak factor (JOPF) for the Synchrony jaw settings were 0.964 and 0.983 for the 1.0‐ and 2.5‐cm jaw settings, respectively. These values decreased to 0.925 and 0.982 for the fixed‐width settings, indicating that the peak value of the profile would decrease by 7.5% compared to centered if the aperture width was held constant. The IMRT dose distributions reveal similar results, where gamma pass rates are above tolerance for the Synchrony jaw settings but fall significantly for the fixed‐width 1‐cm jaws. Conclusions: The variable‐width behavior of Synchrony jaws provides a larger output correction for the 1‐cm jaw setting. Without the variable‐aperture correction, plans with the 1‐cm jaw setting would underdose the target if the jaws spend a significant amount of time in the extreme positions. This work investigated the change in delivered dose with jaws in the extreme positions, therefore overall changes in dose due to offset jaws are expected to be less for composite treatment deliveries. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 5(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 5(2021)
- Issue Display:
- Volume 22, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 5
- Issue Sort Value:
- 2021-0022-0005-0000
- Page Start:
- 175
- Page End:
- 181
- Publication Date:
- 2021-03-29
- Subjects:
- radixact -- synchrony -- tomotherapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13234 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16820.xml