Impact of slice thickness, pixel size, and CT dose on the performance of automatic contouring algorithms. Issue 5 (29th March 2021)
- Record Type:
- Journal Article
- Title:
- Impact of slice thickness, pixel size, and CT dose on the performance of automatic contouring algorithms. Issue 5 (29th March 2021)
- Main Title:
- Impact of slice thickness, pixel size, and CT dose on the performance of automatic contouring algorithms
- Authors:
- Huang, Kai
Rhee, Dong Joo
Ger, Rachel
Layman, Rick
Yang, Jinzhong
Cardenas, Carlos E.
Court, Laurence E. - Abstract:
- Abstract: Purpose: To investigate the impact of computed tomography (CT) image acquisition and reconstruction parameters, including slice thickness, pixel size, and dose, on automatic contouring algorithms. Methods: Eleven scans from patients with head‐and‐neck cancer were reconstructed with varying slice thicknesses and pixel sizes. CT dose was varied by adding noise using low‐dose simulation software. The impact of these imaging parameters on two in‐house auto‐contouring algorithms, one convolutional neural network (CNN)‐based and one multiatlas‐based system (MACS) was investigated for 183 reconstructed scans. For each algorithm, auto‐contours for organs‐at‐risk were compared with auto‐contours from scans with 3 mm slice thickness, 0.977 mm pixel size, and 100% CT dose using Dice similarity coefficient (DSC), Hausdorff distance (HD), and mean surface distance (MSD). Results: Increasing the slice thickness from baseline value of 3 mm gave a progressive reduction in DSC and an increase in HD and MSD on average for all structures. Reducing the CT dose only had a relatively minimal effect on DSC and HD. The rate of change with respect to dose for both auto‐contouring methods is approximately 0. Changes in pixel size had a small effect on DSC and HD for CNN‐based auto‐contouring with differences in DSC being within 0.07. Small structures had larger deviations from the baseline values than large structures for DSC. The relative differences in HD and MSD between the large andAbstract: Purpose: To investigate the impact of computed tomography (CT) image acquisition and reconstruction parameters, including slice thickness, pixel size, and dose, on automatic contouring algorithms. Methods: Eleven scans from patients with head‐and‐neck cancer were reconstructed with varying slice thicknesses and pixel sizes. CT dose was varied by adding noise using low‐dose simulation software. The impact of these imaging parameters on two in‐house auto‐contouring algorithms, one convolutional neural network (CNN)‐based and one multiatlas‐based system (MACS) was investigated for 183 reconstructed scans. For each algorithm, auto‐contours for organs‐at‐risk were compared with auto‐contours from scans with 3 mm slice thickness, 0.977 mm pixel size, and 100% CT dose using Dice similarity coefficient (DSC), Hausdorff distance (HD), and mean surface distance (MSD). Results: Increasing the slice thickness from baseline value of 3 mm gave a progressive reduction in DSC and an increase in HD and MSD on average for all structures. Reducing the CT dose only had a relatively minimal effect on DSC and HD. The rate of change with respect to dose for both auto‐contouring methods is approximately 0. Changes in pixel size had a small effect on DSC and HD for CNN‐based auto‐contouring with differences in DSC being within 0.07. Small structures had larger deviations from the baseline values than large structures for DSC. The relative differences in HD and MSD between the large and small structures were small. Conclusions: Auto‐contours can deviate substantially with changes in CT acquisition and reconstruction parameters, especially slice thickness and pixel size. The CNN was less sensitive to changes in pixel size, and dose levels than the MACS. The results contraindicated more restrictive values for the parameters should be used than a typical imaging protocol for head‐and‐neck. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 5(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 5(2021)
- Issue Display:
- Volume 22, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 5
- Issue Sort Value:
- 2021-0022-0005-0000
- Page Start:
- 168
- Page End:
- 174
- Publication Date:
- 2021-03-29
- Subjects:
- atlas‐based segmentation -- auto‐contouring -- convolutional neural network -- CT parameters
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13207 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16820.xml