Revealing the mechanisms behind novel auditory stimuli discrimination: An evaluation of silent functional MRI using looping star. Issue 9 (17th March 2021)
- Record Type:
- Journal Article
- Title:
- Revealing the mechanisms behind novel auditory stimuli discrimination: An evaluation of silent functional MRI using looping star. Issue 9 (17th March 2021)
- Main Title:
- Revealing the mechanisms behind novel auditory stimuli discrimination: An evaluation of silent functional MRI using looping star
- Authors:
- Damestani, Nikou L.
O'Daly, Owen
Solana, Ana Beatriz
Wiesinger, Florian
Lythgoe, David J.
Hill, Simon
de Lara Rubio, Alfonso
Makovac, Elena
Williams, Steven C. R.
Zelaya, Fernando - Abstract:
- Abstract: Looping Star is a near‐silent, multi‐echo, 3D functional magnetic resonance imaging (fMRI) technique. It reduces acoustic noise by at least 25dBA, with respect to gradient‐recalled echo echo‐planar imaging (GRE‐EPI)‐based fMRI. Looping Star has successfully demonstrated sensitivity to the cerebral blood‐oxygen‐level‐dependent (BOLD) response during block design paradigms but has not been applied to event‐related auditory perception tasks. Demonstrating Looping Star's sensitivity to such tasks could (a) provide new insights into auditory processing studies, (b) minimise the need for invasive ear protection, and (c) facilitate the translation of numerous fMRI studies to investigations in sound‐averse patients. We aimed to demonstrate, for the first time, that multi‐echo Looping Star has sufficient sensitivity to the BOLD response, compared to that of GRE‐EPI, during a well‐established event‐related auditory discrimination paradigm: the "oddball" task. We also present the first quantitative evaluation of Looping Star's test–retest reliability using the intra‐class correlation coefficient. Twelve participants were scanned using single‐echo GRE‐EPI and multi‐echo Looping Star fMRI in two sessions. Random‐effects analyses were performed, evaluating the overall response to tones and differential tone recognition, and intermodality analyses were computed. We found that multi‐echo Looping Star exhibited consistent sensitivity to auditory stimulation relative to GRE‐EPI.Abstract: Looping Star is a near‐silent, multi‐echo, 3D functional magnetic resonance imaging (fMRI) technique. It reduces acoustic noise by at least 25dBA, with respect to gradient‐recalled echo echo‐planar imaging (GRE‐EPI)‐based fMRI. Looping Star has successfully demonstrated sensitivity to the cerebral blood‐oxygen‐level‐dependent (BOLD) response during block design paradigms but has not been applied to event‐related auditory perception tasks. Demonstrating Looping Star's sensitivity to such tasks could (a) provide new insights into auditory processing studies, (b) minimise the need for invasive ear protection, and (c) facilitate the translation of numerous fMRI studies to investigations in sound‐averse patients. We aimed to demonstrate, for the first time, that multi‐echo Looping Star has sufficient sensitivity to the BOLD response, compared to that of GRE‐EPI, during a well‐established event‐related auditory discrimination paradigm: the "oddball" task. We also present the first quantitative evaluation of Looping Star's test–retest reliability using the intra‐class correlation coefficient. Twelve participants were scanned using single‐echo GRE‐EPI and multi‐echo Looping Star fMRI in two sessions. Random‐effects analyses were performed, evaluating the overall response to tones and differential tone recognition, and intermodality analyses were computed. We found that multi‐echo Looping Star exhibited consistent sensitivity to auditory stimulation relative to GRE‐EPI. However, Looping Star demonstrated lower test–retest reliability in comparison with GRE‐EPI. This could reflect differences in functional sensitivity between the techniques, though further study is necessary with additional cognitive paradigms as varying cognitive strategies between sessions may arise from elimination of acoustic scanner noise. Abstract : Looping Star is a new multi‐echo functional magnetic resonance imaging technique (fMRI) that reduces acoustic noise of scanning by at least 25dBA, with respect to gradient‐recalled echo echo‐planar imaging (GRE‐EPI)‐based fMRI. We demonstrate, for the first time, that multi‐echo Looping Star is sensitive to the BOLD response during the auditory "oddball" task, an event‐related discrimination paradigm. This is also the first study to evaluate the test‐retest reliability of Looping Star in comparison with GRE‐EPI. … (more)
- Is Part Of:
- Human brain mapping. Volume 42:Issue 9(2021)
- Journal:
- Human brain mapping
- Issue:
- Volume 42:Issue 9(2021)
- Issue Display:
- Volume 42, Issue 9 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 9
- Issue Sort Value:
- 2021-0042-0009-0000
- Page Start:
- 2833
- Page End:
- 2850
- Publication Date:
- 2021-03-17
- Subjects:
- auditory oddball -- Looping Star -- novel sounds -- silent functional MRI -- tone discrimination
Brain mapping -- Periodicals
611.81 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-0193 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/hbm.25407 ↗
- Languages:
- English
- ISSNs:
- 1065-9471
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4336.031000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16810.xml