Reliability and validity of the timed 360° turn test in people with multiple sclerosis. (3rd June 2021)
- Record Type:
- Journal Article
- Title:
- Reliability and validity of the timed 360° turn test in people with multiple sclerosis. (3rd June 2021)
- Main Title:
- Reliability and validity of the timed 360° turn test in people with multiple sclerosis
- Authors:
- Soke, Fatih
Guclu-Gunduz, Arzu
Ozkul, Cagla
Cekim, Kader
Irkec, Ceyla
Gonenli Kocer, Bilge - Abstract:
- ABSTRACT: Objectives : To investigate (1) the intrarater, interrater, and test–retest reliability of the timed 360° turn test in people with Multiple Sclerosis (MS); (2) the minimum detectable change in the timed 360° turn test times; (3) the concurrent and discriminant validity of the timed 360° turn test times; and (4) the cut-off times that best discriminate people with MS from healthy people and fallers from non-fallers with MS. Method : Sixty-one people with MS (Expanded Disability Status Scale, EDSS, 0–6.5) and 34 healthy people were recruited in this cross-sectional study. The timed 360° turn test was administered along with the Timed Up and Go Test, Berg Balance Scale, Four Square Step Test, and EDSS by two independent raters. Results : The timed 360° turn test showed good intrarater, interrater, and test–retest reliability. Minimal detectable changes were 1.49 s and 1.53 s for the dominant and non-dominant sides, respectively. The timed 360° turn test was strongly correlated with other outcome measures. Significant differences in 360° turn times were found between people with MS and healthy people and between fallers and non-fallers with MS ( p < .001 and p < .001, respectively). The cut-off times of 2.65 s on the dominant side and 2.42 s on the non-dominant best discriminated people with MS from healthy people, while 3.65 s on the dominant side and 3.75 s on the non-dominant best discriminated fallers from non-fallers with MS. Conclusions : The timed 360° turn testABSTRACT: Objectives : To investigate (1) the intrarater, interrater, and test–retest reliability of the timed 360° turn test in people with Multiple Sclerosis (MS); (2) the minimum detectable change in the timed 360° turn test times; (3) the concurrent and discriminant validity of the timed 360° turn test times; and (4) the cut-off times that best discriminate people with MS from healthy people and fallers from non-fallers with MS. Method : Sixty-one people with MS (Expanded Disability Status Scale, EDSS, 0–6.5) and 34 healthy people were recruited in this cross-sectional study. The timed 360° turn test was administered along with the Timed Up and Go Test, Berg Balance Scale, Four Square Step Test, and EDSS by two independent raters. Results : The timed 360° turn test showed good intrarater, interrater, and test–retest reliability. Minimal detectable changes were 1.49 s and 1.53 s for the dominant and non-dominant sides, respectively. The timed 360° turn test was strongly correlated with other outcome measures. Significant differences in 360° turn times were found between people with MS and healthy people and between fallers and non-fallers with MS ( p < .001 and p < .001, respectively). The cut-off times of 2.65 s on the dominant side and 2.42 s on the non-dominant best discriminated people with MS from healthy people, while 3.65 s on the dominant side and 3.75 s on the non-dominant best discriminated fallers from non-fallers with MS. Conclusions : The timed 360° turn test is a simple and reliable tool for assessing turning ability in MS. … (more)
- Is Part Of:
- Physiotherapy theory and practice. Volume 37:Number 6(2021)
- Journal:
- Physiotherapy theory and practice
- Issue:
- Volume 37:Number 6(2021)
- Issue Display:
- Volume 37, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 37
- Issue:
- 6
- Issue Sort Value:
- 2021-0037-0006-0000
- Page Start:
- 736
- Page End:
- 747
- Publication Date:
- 2021-06-03
- Subjects:
- Multiple sclerosis -- outcome measures -- rehabilitation -- reliability -- validity
Physical therapy -- Periodicals
615.82 - Journal URLs:
- http://informahealthcare.com/loi/ptp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/09593985.2019.1641867 ↗
- Languages:
- English
- ISSNs:
- 0959-3985
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6489.140000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16803.xml