Differences in measurement of high-sensitivity troponin in an on-demand and batch-wise setting. Issue 3 (23rd July 2020)
- Record Type:
- Journal Article
- Title:
- Differences in measurement of high-sensitivity troponin in an on-demand and batch-wise setting. Issue 3 (23rd July 2020)
- Main Title:
- Differences in measurement of high-sensitivity troponin in an on-demand and batch-wise setting
- Authors:
- Sörensen, Nils Arne
Neumann, Johannes Tobias
Ojeda, Francisco
Renné, Thomas
Karakas, Mahir
Blankenberg, Stefan
Westermann, Dirk
Zeller, Tanja - Abstract:
- Abstract: Background: Most studies assessing the diagnostic value of high-sensitivity troponin in the diagnosis of myocardial infarction used batch-wise analyses of frozen samples for high-sensitivity troponin measurements. Whether the accuracy of these batch-wise high-sensitivity troponin measurements described in diagnostic studies is comparable to clinical routine is unknown. Methods: We enrolled 937 patients presenting with suspected myocardial infarction in this prospective cohort study. Measurements of high-sensitivity troponin I (Abbott Architect) and high-sensitivity troponin T (Roche) were performed in two settings: (a) on-demand in clinical routine using fresh blood samples; and (b) in batches using frozen blood samples from the same individuals at three timepoints (0 hours, 1 hour and 3 hours after presentation). Results: Median troponin levels were not different between on-demand and batch-wise measurements. Troponin levels in the range of 0 to 40 ng/L showed a very high correlation between the on-demand and batch setting (Pearson correlation coefficient ( r ) was 0.92–0.95 for high-sensitivity troponin I and 0.96 for high-sensitivity troponin T). However, at very low troponin levels (0 to 10 ng/L) correlation between the two settings was moderate ( r for high-sensitivity troponin I 0.59–0.66 and 0.65–0.69 for high-sensitivity troponin T). Application of guideline-recommended rapid diagnostic algorithms showed similar diagnostic performance with both methods.Abstract: Background: Most studies assessing the diagnostic value of high-sensitivity troponin in the diagnosis of myocardial infarction used batch-wise analyses of frozen samples for high-sensitivity troponin measurements. Whether the accuracy of these batch-wise high-sensitivity troponin measurements described in diagnostic studies is comparable to clinical routine is unknown. Methods: We enrolled 937 patients presenting with suspected myocardial infarction in this prospective cohort study. Measurements of high-sensitivity troponin I (Abbott Architect) and high-sensitivity troponin T (Roche) were performed in two settings: (a) on-demand in clinical routine using fresh blood samples; and (b) in batches using frozen blood samples from the same individuals at three timepoints (0 hours, 1 hour and 3 hours after presentation). Results: Median troponin levels were not different between on-demand and batch-wise measurements. Troponin levels in the range of 0 to 40 ng/L showed a very high correlation between the on-demand and batch setting (Pearson correlation coefficient ( r ) was 0.92–0.95 for high-sensitivity troponin I and 0.96 for high-sensitivity troponin T). However, at very low troponin levels (0 to 10 ng/L) correlation between the two settings was moderate ( r for high-sensitivity troponin I 0.59–0.66 and 0.65–0.69 for high-sensitivity troponin T). Application of guideline-recommended rapid diagnostic algorithms showed similar diagnostic performance with both methods. Conclusions: Overall on-demand and batch-wise measurements of high-sensitivity troponin provided similar results, but their correlation was moderate, when focusing on very low troponin levels. The application of rapid diagnostic algorithms was safe in both settings. Trial Registration: www.clinicaltrials.gov (NCT02355457) … (more)
- Is Part Of:
- European heart journal. Volume 10:Issue 3(2021)
- Journal:
- European heart journal
- Issue:
- Volume 10:Issue 3(2021)
- Issue Display:
- Volume 10, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 10
- Issue:
- 3
- Issue Sort Value:
- 2021-0010-0003-0000
- Page Start:
- 302
- Page End:
- 309
- Publication Date:
- 2020-07-23
- Subjects:
- Troponin I -- troponin T -- batch -- on-demand -- clinical routine -- high-sensitivity -- myocardial infarction
616.1205 - Journal URLs:
- https://academic.oup.com/ehjacc/issue ↗
http://acc.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/2048872620924198 ↗
- Languages:
- English
- ISSNs:
- 2048-8726
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16795.xml