Construction of dose response curve for 6 MV LINAC X-rays using Premature Chromosome Condensation assay for radiation dosimetry. (July 2021)
- Record Type:
- Journal Article
- Title:
- Construction of dose response curve for 6 MV LINAC X-rays using Premature Chromosome Condensation assay for radiation dosimetry. (July 2021)
- Main Title:
- Construction of dose response curve for 6 MV LINAC X-rays using Premature Chromosome Condensation assay for radiation dosimetry
- Authors:
- Meenakshi, C.
Venkatachalam, P.
Chandrasekaran, S.
Venkatraman, B. - Abstract:
- Abstract: Quantification of chromosomal aberrations in the exposed personnel blood samples is considered as a 'gold standard' and sensitive biomarker in biological dosimetry. Despite technological developments, culture of cells for 48–52 h remains an unmet need in case of triage biodosimetry. Moreover, it is difficult to get sufficient number of metaphase spreads for scoring after high doses of exposures. The technique which causes condensation of chromatin before mitosis using biological or chemical agent is named as Premature Chromosome Condensation (PCC) assay. This assay is considered as an alternative to chromosome aberration assay, particularly at high acute doses of low and high LET radiation. To establish the PCC assay, blood samples were collected from healthy non-smoking individuals (n = 3) and exposed to various doses (0–20 Gy) of 6 MV X-rays at a dose rate of 5.6 Gy/min, using a high energy Linear accelerator (LINAC). Irradiated blood samples were subjected to Calyculin-A induced PCC. About 500 cells or more than 100 Ring Chromosomes (RC) were scored at each dose. Dicentric chromosomes (DC) and acentric fragments were also scored at each dose; the number of chromosomal aberrations in G1, M, G2/M and M/A phase of cell cycle were recorded and the frequency was used to construct the dose response curve. A dose dependent increase in RC and DC frequency were observed with a slope of 0.049 ± 0.002 and 0.30 ± 0.02 respectively. This study is first of its kind toAbstract: Quantification of chromosomal aberrations in the exposed personnel blood samples is considered as a 'gold standard' and sensitive biomarker in biological dosimetry. Despite technological developments, culture of cells for 48–52 h remains an unmet need in case of triage biodosimetry. Moreover, it is difficult to get sufficient number of metaphase spreads for scoring after high doses of exposures. The technique which causes condensation of chromatin before mitosis using biological or chemical agent is named as Premature Chromosome Condensation (PCC) assay. This assay is considered as an alternative to chromosome aberration assay, particularly at high acute doses of low and high LET radiation. To establish the PCC assay, blood samples were collected from healthy non-smoking individuals (n = 3) and exposed to various doses (0–20 Gy) of 6 MV X-rays at a dose rate of 5.6 Gy/min, using a high energy Linear accelerator (LINAC). Irradiated blood samples were subjected to Calyculin-A induced PCC. About 500 cells or more than 100 Ring Chromosomes (RC) were scored at each dose. Dicentric chromosomes (DC) and acentric fragments were also scored at each dose; the number of chromosomal aberrations in G1, M, G2/M and M/A phase of cell cycle were recorded and the frequency was used to construct the dose response curve. A dose dependent increase in RC and DC frequency were observed with a slope of 0.049 ± 0.002 and 0.30 ± 0.02 respectively. This study is first of its kind to construct a dose response curve for LINAC X-rays using a PCC assay. Highlights: This study is first of its kind to construct dose response curve for LINAC X-rays using PCC assay. Chemically induced PCC is very reliable biodosimetry tool for accidental exposure. PCC rings observed to be appropriate biomarker for high dose exposure. Different types of PCC rings observed in various phases of cell cycle (G2/M, M, M/A) are shown. It is shown that the dicentric chromosomes are suitable only for low dose exposure (<5 Gy). … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 173(2021)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 173(2021)
- Issue Display:
- Volume 173, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 173
- Issue:
- 2021
- Issue Sort Value:
- 2021-0173-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-07
- Subjects:
- Dose response curve -- High dose radiation -- PCC assay -- Calyculin A -- LINAC X-rays
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2021.109729 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16771.xml