Dosimetric effect of nanoparticles in the breast cancer treatment using INTRABEAM® system with spherical applicators in the presence of tissue heterogeneities: A Monte Carlo study. (28th April 2021)
- Record Type:
- Journal Article
- Title:
- Dosimetric effect of nanoparticles in the breast cancer treatment using INTRABEAM® system with spherical applicators in the presence of tissue heterogeneities: A Monte Carlo study. (28th April 2021)
- Main Title:
- Dosimetric effect of nanoparticles in the breast cancer treatment using INTRABEAM® system with spherical applicators in the presence of tissue heterogeneities: A Monte Carlo study
- Authors:
- Tegaw, Eyachew Misganew
Geraily, Ghazale
Etesami, Seyed Mohsen
Ghanbari, Hossein
Gholami, Somayeh
Shojaei, Mehdi
Farzin, Mostafa
Tadesse, Getu Ferenji - Abstract:
- Abstract: Using the 50 kV INTRABEAM ® IORT system after breast-conserving surgery: tumor recurrence and organs at risk (OARs), such as the lung and heart, long-term complications remain the challenging problems for breast cancer patients. So, the objective of this study was to address these two problems with the help of high atomic number nanoparticles (NPs). A Monte Carlo (MC) Simulation type EGSnrc C++ class library (egspp) with its Easy particle propagation (Epp) user code was used. The simulation was validated against the measured depth dose data found in our previous study (Tegaw, et al 2020 Dosimetric characteristics of the INTRABEAM ® system with spherical applicators in the presence of air gaps and tissue heterogeneities, Radiat. Environ. Biophys . (10.1007/s00411-020-00835-0)) using the gamma index and passed 2%/2 mm acceptance criteria in the gamma analysis. Gold (Au) NPs were selected after comparing Dose Enhancement Ratios (DERs) of bismuth (Bi), Au, and platinum (Pt) NPs which were calculated from the simulated results. As a result, 0.02, 0.2, 2, 10, and 20 mg-Au/g-breast tissue were used throughout this study. These particles were not distributed in discrete but in a uniform concentration. For 20 mg-Au/g-breast tissue, the DERs were 3.6, 0.420, and 0.323 for breast tissue, lung, heart, respectively, using the 1.5 cm-diameter applicator (AP) and 3.61, 0.428, and 0.335 forbreast tissue, lung, and heart using the 5 cm-diameter applicator, respectively. DERAbstract: Using the 50 kV INTRABEAM ® IORT system after breast-conserving surgery: tumor recurrence and organs at risk (OARs), such as the lung and heart, long-term complications remain the challenging problems for breast cancer patients. So, the objective of this study was to address these two problems with the help of high atomic number nanoparticles (NPs). A Monte Carlo (MC) Simulation type EGSnrc C++ class library (egspp) with its Easy particle propagation (Epp) user code was used. The simulation was validated against the measured depth dose data found in our previous study (Tegaw, et al 2020 Dosimetric characteristics of the INTRABEAM ® system with spherical applicators in the presence of air gaps and tissue heterogeneities, Radiat. Environ. Biophys . (10.1007/s00411-020-00835-0)) using the gamma index and passed 2%/2 mm acceptance criteria in the gamma analysis. Gold (Au) NPs were selected after comparing Dose Enhancement Ratios (DERs) of bismuth (Bi), Au, and platinum (Pt) NPs which were calculated from the simulated results. As a result, 0.02, 0.2, 2, 10, and 20 mg-Au/g-breast tissue were used throughout this study. These particles were not distributed in discrete but in a uniform concentration. For 20 mg-Au/g-breast tissue, the DERs were 3.6, 0.420, and 0.323 for breast tissue, lung, heart, respectively, using the 1.5 cm-diameter applicator (AP) and 3.61, 0.428, and 0.335 forbreast tissue, lung, and heart using the 5 cm-diameter applicator, respectively. DER increased with the decrease in the depth of tissues and increase in the effective atomic number (Zeff ) and concentration of Au NPs, however, there was no significant change as AP sizes increased. Therefore, Au NPs showed dual advantages such as dose enhancement within the tumor bed and reduction in the OARs (heart and lung). … (more)
- Is Part Of:
- Biomedical physics & engineering express. Volume 7:Number 3(2021)
- Journal:
- Biomedical physics & engineering express
- Issue:
- Volume 7:Number 3(2021)
- Issue Display:
- Volume 7, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 7
- Issue:
- 3
- Issue Sort Value:
- 2021-0007-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04-28
- Subjects:
- Dose enhancement -- dose reduction -- nanoparticles -- INTRABEAM® IORT system -- EGSnrc Simulation
Medical physics -- Periodicals
Biophysics -- Periodicals
Biomedical engineering -- Periodicals
Medical sciences -- Periodicals
610.153 - Journal URLs:
- http://iopscience.iop.org/2057-1976/ ↗
http://www.iop.org/ ↗ - DOI:
- 10.1088/2057-1976/abf6a9 ↗
- Languages:
- English
- ISSNs:
- 2057-1976
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16781.xml