A new contrast-to-noise ratio for image quality characterization of a coded-aperture γ camera. (April 2021)
- Record Type:
- Journal Article
- Title:
- A new contrast-to-noise ratio for image quality characterization of a coded-aperture γ camera. (April 2021)
- Main Title:
- A new contrast-to-noise ratio for image quality characterization of a coded-aperture γ camera
- Authors:
- Zhu, Balin
Wang, Zhonghai
Gao, Tai
Chen, Qi
Huang, Qichang
Mao, Xiaoqin
Zhao, Chaoyang
Tao, Mingrui
Qi, Peiwen
Zhao, Qianru
Li, Yulong
Zhou, Rong
Yang, Chaowen - Abstract:
- Abstract: The gamma-ray imaging technique was developed and is widely used in several nuclear engineering fields. Specifically, compared with the traditional point-by-point radiation detector, the coded-aperture gamma camera has advantages of a wide field of view, high angular resolution, and high efficiency. Several methods for characterizing image quality, including the figure of merit (FOM) method and the contrast-to-noise ratio (CNR) method, were assessed and developed. These methods have their respective drawbacks depending on the circumstances. The FOM lacks reliability in exhibiting the impact of background noise fluctuation on the purity of a real image. The CNR characterizes image quality with inconsistent sensitivity while the source moves along the X and Y directions. Therefore, a new CNR method was proposed to achieve better performance and greater consistency in real imaging. With our coded-aperture imaging system developed in the laboratory, we performed simulations within the MATLAB and Geant4 platforms and real imaging experiments to analyze and compare images and the results of these three characterization methods. The results show that the new CNR method is reliable and practical in regard to real imaging performance. Highlights: A new characterization method for image quality derived from present methods is proposed for a coded-aperture gamma camera. The new method was evaluated by MATLAB calculation, Geant4 simulation, and experiment with a custom-madeAbstract: The gamma-ray imaging technique was developed and is widely used in several nuclear engineering fields. Specifically, compared with the traditional point-by-point radiation detector, the coded-aperture gamma camera has advantages of a wide field of view, high angular resolution, and high efficiency. Several methods for characterizing image quality, including the figure of merit (FOM) method and the contrast-to-noise ratio (CNR) method, were assessed and developed. These methods have their respective drawbacks depending on the circumstances. The FOM lacks reliability in exhibiting the impact of background noise fluctuation on the purity of a real image. The CNR characterizes image quality with inconsistent sensitivity while the source moves along the X and Y directions. Therefore, a new CNR method was proposed to achieve better performance and greater consistency in real imaging. With our coded-aperture imaging system developed in the laboratory, we performed simulations within the MATLAB and Geant4 platforms and real imaging experiments to analyze and compare images and the results of these three characterization methods. The results show that the new CNR method is reliable and practical in regard to real imaging performance. Highlights: A new characterization method for image quality derived from present methods is proposed for a coded-aperture gamma camera. The new method was evaluated by MATLAB calculation, Geant4 simulation, and experiment with a custom-made gamma camera. The performances of the two present characterization methods and the new method were compared and analyzed. The new evaluation method is more reliable and more practical than the two present methods. … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 170(2021)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 170(2021)
- Issue Display:
- Volume 170, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 170
- Issue:
- 2021
- Issue Sort Value:
- 2021-0170-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04
- Subjects:
- Gamma imaging -- Image quality -- Characterization method -- Coded aperture
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2021.109592 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16767.xml