Comparison of acute and long‐term outcomes of Evolution® and TightRail™ mechanical dilator sheaths during transvenous lead extraction. (25th March 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of acute and long‐term outcomes of Evolution® and TightRail™ mechanical dilator sheaths during transvenous lead extraction. (25th March 2021)
- Main Title:
- Comparison of acute and long‐term outcomes of Evolution® and TightRail™ mechanical dilator sheaths during transvenous lead extraction
- Authors:
- Bahadır, Nihan
Canpolat, Ugur
Kaya, Ergun B.
Sahiner, Mehmet L.
Ateş, Ahmet H.
Yorgun, Hikmet
Aytemir, Kudret - Abstract:
- Abstract: Background: Powered transvenous lead extraction (TLE) tools are commonly required to remove the leads with long implant duration due to fibrotic adhesions. However, comparative data are lacking among different types of TLE tools. Aim: To compare the efficacy and safety of two different rotational mechanical dilator sheaths in retrospectively analyzed patients who underwent TLE. Methods and Results: A total of 566 lead extractions from 302 patients using TightRail™ (333 lead extractions from 169 patients) and Evolution ® (233 lead extractions from 133 patients) mechanical dilator sheaths were performed between July 2009 and June 2018. Acute and long‐term outcomes of study groups were compared. There is no statistically significant difference between Evolution ® and TightRail™ groups in procedural success (93.9% vs. 94%), clinical success (99.2% vs. 98%), and major complications (3.8% vs. 1.2%), respectively ( p > .05). In multivariate regression analysis, lead dwell time, the number of extracted leads, and baseline leukocyte count were found as independent predictors of procedural success ( p < .05). During the median follow‐up of 36.6 (0.2–118) months, all‐cause mortality was observed in 73 patients (25.6% in the Evolution ® vs. 23.1 in the TightRail™ group, p > .05). Chronic renal disease, heart failure, and coagulopathy were shown as independent predictors of all‐cause mortality in multivariate regression analysis ( p < .05). Conclusion: TLE usingAbstract: Background: Powered transvenous lead extraction (TLE) tools are commonly required to remove the leads with long implant duration due to fibrotic adhesions. However, comparative data are lacking among different types of TLE tools. Aim: To compare the efficacy and safety of two different rotational mechanical dilator sheaths in retrospectively analyzed patients who underwent TLE. Methods and Results: A total of 566 lead extractions from 302 patients using TightRail™ (333 lead extractions from 169 patients) and Evolution ® (233 lead extractions from 133 patients) mechanical dilator sheaths were performed between July 2009 and June 2018. Acute and long‐term outcomes of study groups were compared. There is no statistically significant difference between Evolution ® and TightRail™ groups in procedural success (93.9% vs. 94%), clinical success (99.2% vs. 98%), and major complications (3.8% vs. 1.2%), respectively ( p > .05). In multivariate regression analysis, lead dwell time, the number of extracted leads, and baseline leukocyte count were found as independent predictors of procedural success ( p < .05). During the median follow‐up of 36.6 (0.2–118) months, all‐cause mortality was observed in 73 patients (25.6% in the Evolution ® vs. 23.1 in the TightRail™ group, p > .05). Chronic renal disease, heart failure, and coagulopathy were shown as independent predictors of all‐cause mortality in multivariate regression analysis ( p < .05). Conclusion: TLE using TightRail™ or Evoluation ® mechanical dilator sheaths was a safe and effective therapeutic option. Both mechanical dilator sheaths showed similar efficacy, safety, and all‐cause mortality at acute and long‐term follow‐up of patients who underwent TLE. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 32:Number 5(2021)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 32:Number 5(2021)
- Issue Display:
- Volume 32, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 5
- Issue Sort Value:
- 2021-0032-0005-0000
- Page Start:
- 1395
- Page End:
- 1404
- Publication Date:
- 2021-03-25
- Subjects:
- mechanical rotational sheath -- mortality -- success -- transvenous lead extraction
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.15006 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16750.xml