Impact of preoperative arterial and venous diameter on achievement of the adequate blood flow in arteriovenous fistula for hemodialysis. Issue 3 (24th August 2020)
- Record Type:
- Journal Article
- Title:
- Impact of preoperative arterial and venous diameter on achievement of the adequate blood flow in arteriovenous fistula for hemodialysis. Issue 3 (24th August 2020)
- Main Title:
- Impact of preoperative arterial and venous diameter on achievement of the adequate blood flow in arteriovenous fistula for hemodialysis
- Authors:
- Gjorgjievski, Nikola
Dzekova‐Vidimliski, Pavlina
Trajcheska, Lada
Stojanoska, Ana
Selim, Gjulshen
Rambabova‐Bushljetik, Irena
Nikolov, Igor
Gjorgievska, Juija
Janevski, Zoran
Muharremi, Shkleqim
Dejanov, Petar
Spasovski, Goce
Sikole, Aleksandar
Ivanovski, Ninoslav - Abstract:
- Abstract: An arteriovenous fistula (AVF) remains the best choice of vascular access (VA) for hemodialysis (HD). The aim of the study was to determine the factors associated with the achievement of adequate blood flow (BF) of AVFs at the 4th week after creation. Created AVFs in 63 patients with chronic kidney disease (CKD) stage 4/5 and CKD stage 5 on hemodialysis (CKD5D) were analyzed in a prospective study. Doppler ultrasound (DUS) was used for measuring the diameter of the radial artery, the brachial artery and the cephalic vein before AVF creation. The BF of AVF was calculated by DUS at the 4th week after creation and adequate BF was defined as ≥ 600 mL/min. The average age of patients was 61.31 ± 12.9 years. An adequate BF of AVF at the 4th week after creation was achieved in 43.54% of patients. The BF of AVF measured in male patients was significantly higher compared to the BF of AVF obtained in females (576.03 mL/min vs 375.12 mL/min, P = 0.004). The diameter of the blood vessels with achieved adequate BF was significantly larger compared to the diameter of the blood vessels without adequate BF (radial artery: 2.45 mm vs 2.03 mm, P = 0.000; brachial artery: 4.78 mm vs 4.06 mm, P = 0.001 and cephalic vein: 3.12 mm vs 2.83 mm P = 0.018). The gender and the diameter of the blood vessels before AVF creation were significantly associated with achievement of adequate BF of AVF at the 4th week of creation.
- Is Part Of:
- Therapeutic apheresis and dialysis. Volume 25:Issue 3(2021)
- Journal:
- Therapeutic apheresis and dialysis
- Issue:
- Volume 25:Issue 3(2021)
- Issue Display:
- Volume 25, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 25
- Issue:
- 3
- Issue Sort Value:
- 2021-0025-0003-0000
- Page Start:
- 273
- Page End:
- 281
- Publication Date:
- 2020-08-24
- Subjects:
- arteriovenous fistula -- blood flow -- blood vessels -- Doppler ultrasound -- hemodialysis patients
Hemapheresis -- Periodicals
Dialysis -- Periodicals
Blood Component Removal -- Periodicals
Renal Dialysis -- Periodicals
Hémaphérèse -- Périodiques
Dialyse -- Périodiques
Sang -- Collecte et conservation -- Périodiques
616 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1744-9979;screen=info;ECOIP ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1744-9987 ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=tap ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/rd.asp?code=TAP&goto=journal ↗ - DOI:
- 10.1111/1744-9987.13570 ↗
- Languages:
- English
- ISSNs:
- 1744-9979
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8814.642670
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16717.xml