A comparison of the efficacy, safety, and duration of frame-based and Remebot robot-assisted frameless stereotactic biopsy. (4th May 2021)
- Record Type:
- Journal Article
- Title:
- A comparison of the efficacy, safety, and duration of frame-based and Remebot robot-assisted frameless stereotactic biopsy. (4th May 2021)
- Main Title:
- A comparison of the efficacy, safety, and duration of frame-based and Remebot robot-assisted frameless stereotactic biopsy
- Authors:
- Wu, Shiqiang
Wang, Junwen
Gao, Pan
Liu, Weihua
Hu, Feng
Jiang, Wei
Lei, Ting
Shu, Kai - Abstract:
- Abstract: Objective: The aim of this study was to compare the efficacy, safety, and duration of Remebot robot-assisted frameless brain biopsy with those of standard frame-based stereotactic biopsy. Patients and methods: A retrospective analysis of 66 patients undergoing stereotactic brain biopsy in our department from January 2015 to January 2019 was performed. We divided the patients into two groups: the frame-based group ( n = 35) and the Remebot robot group ( n = 31). Data on clinical characteristics, total procedure length, overall discomfort, diagnostic yield, complications, and postoperative length of hospital stay were retrospectively reviewed and compared between these two groups. Results: No significant difference in diagnostic yield was detected in the two groups, with frame-based biopsy having a diagnostic yield of 91.4% and Remebot robot-assisted frameless brain biopsy having a diagnostic yield of 93.5%. The duration of the total procedure was 116.5 min for the frame-based biopsy and 80.1 min for the Remebot robot-assisted frameless brain biopsy ( p < 0.001). There were no statistically significant differences in complication rate or postoperative duration of hospitalization between the two groups. The overall patient discomfort in the frame-based group was significantly greater than that in the Remebot robot group (visual analog scale score 2.7 ± 1.2 versus 1.5 ± 0.7, p = 0.001). Conclusions: Remebot robot-assisted frameless brain biopsy was as efficaciousAbstract: Objective: The aim of this study was to compare the efficacy, safety, and duration of Remebot robot-assisted frameless brain biopsy with those of standard frame-based stereotactic biopsy. Patients and methods: A retrospective analysis of 66 patients undergoing stereotactic brain biopsy in our department from January 2015 to January 2019 was performed. We divided the patients into two groups: the frame-based group ( n = 35) and the Remebot robot group ( n = 31). Data on clinical characteristics, total procedure length, overall discomfort, diagnostic yield, complications, and postoperative length of hospital stay were retrospectively reviewed and compared between these two groups. Results: No significant difference in diagnostic yield was detected in the two groups, with frame-based biopsy having a diagnostic yield of 91.4% and Remebot robot-assisted frameless brain biopsy having a diagnostic yield of 93.5%. The duration of the total procedure was 116.5 min for the frame-based biopsy and 80.1 min for the Remebot robot-assisted frameless brain biopsy ( p < 0.001). There were no statistically significant differences in complication rate or postoperative duration of hospitalization between the two groups. The overall patient discomfort in the frame-based group was significantly greater than that in the Remebot robot group (visual analog scale score 2.7 ± 1.2 versus 1.5 ± 0.7, p = 0.001). Conclusions: Remebot robot-assisted frameless brain biopsy was as efficacious and safe as standard stereotactic frame-based biopsy. However, frameless biopsy can alleviate the suffering of the patient and reduce the total duration of the procedure. Remebot robot-assisted frameless brain biopsy is easy to use and better accepted by patients than frame-based biopsy. … (more)
- Is Part Of:
- British journal of neurosurgery. Volume 35:Number 3(2021)
- Journal:
- British journal of neurosurgery
- Issue:
- Volume 35:Number 3(2021)
- Issue Display:
- Volume 35, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 35
- Issue:
- 3
- Issue Sort Value:
- 2021-0035-0003-0000
- Page Start:
- 319
- Page End:
- 323
- Publication Date:
- 2021-05-04
- Subjects:
- Brain biopsy -- frame-based stereotaxy -- frameless stereotaxy -- Remebot robot
Nervous system -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://informahealthcare.com/loi/bjn ↗
http://www.tandfonline.com/toc/ibjn20/current ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02688697.2020.1812519 ↗
- Languages:
- English
- ISSNs:
- 0268-8697
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2311.940000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: