Dose–response curves for analyzing of dicentric chromosomes and chromosome translocations following doses of 1000 mGy or less, based on irradiated peripheral blood samples from five healthy individuals. (13th October 2017)
- Record Type:
- Journal Article
- Title:
- Dose–response curves for analyzing of dicentric chromosomes and chromosome translocations following doses of 1000 mGy or less, based on irradiated peripheral blood samples from five healthy individuals. (13th October 2017)
- Main Title:
- Dose–response curves for analyzing of dicentric chromosomes and chromosome translocations following doses of 1000 mGy or less, based on irradiated peripheral blood samples from five healthy individuals
- Authors:
- Abe, Yu
Yoshida, Mitsuaki A
Fujioka, Kurumi
Kurosu, Yumiko
Ujiie, Risa
Yanagi, Aki
Tsuyama, Naohiro
Miura, Tomisato
Inaba, Toshiya
Kamiya, Kenji
Sakai, Akira - Abstract:
- Abstract: In terms of biological dosimetry at the time of radiation exposure, the dicentric chromosome (Dic) assay (DCA) is the gold standard for assessing for the acute phase and chromosome translocation (Tr) analysis is the gold standard for assessing the chronic phase. It is desirable to have individual dose–response curves (DRCs) for each laboratory because the analysis criteria differ between laboratories. We constructed the DRCs for radiation dose estimation (with three methods) using peripheral blood (PB) samples from five healthy individuals. Aliquots were irradiated with one of eight gamma-ray doses (0, 10, 20, 50, 100, 200, 500 or 1000 mGy), then cultured for 48 h. The number of chromosome aberrations (CAs) was analyzed by DCA, using Giemsa staining and centromere-fluorescence in situ hybridization (centromere-FISH) and by chromosome painting (chromosome pairs 1, 2 and 4) for Tr analysis. In DCA, there was large variation between individuals in the frequency of Dics formed, and the slopes of the DRCs were different. In Tr analysis, although variation was observed in the frequency of Tr, the slopes of the DRCs were similar after adjusting the background for age. Good correlation between the irradiation dose and the frequency of CAs formed was observed with these three DRCs. However, performing three different biological dosimetry assays simultaneously on PB from five donors nonetheless results in variation in the frequency of CAs formed, especially at doses of 50Abstract: In terms of biological dosimetry at the time of radiation exposure, the dicentric chromosome (Dic) assay (DCA) is the gold standard for assessing for the acute phase and chromosome translocation (Tr) analysis is the gold standard for assessing the chronic phase. It is desirable to have individual dose–response curves (DRCs) for each laboratory because the analysis criteria differ between laboratories. We constructed the DRCs for radiation dose estimation (with three methods) using peripheral blood (PB) samples from five healthy individuals. Aliquots were irradiated with one of eight gamma-ray doses (0, 10, 20, 50, 100, 200, 500 or 1000 mGy), then cultured for 48 h. The number of chromosome aberrations (CAs) was analyzed by DCA, using Giemsa staining and centromere-fluorescence in situ hybridization (centromere-FISH) and by chromosome painting (chromosome pairs 1, 2 and 4) for Tr analysis. In DCA, there was large variation between individuals in the frequency of Dics formed, and the slopes of the DRCs were different. In Tr analysis, although variation was observed in the frequency of Tr, the slopes of the DRCs were similar after adjusting the background for age. Good correlation between the irradiation dose and the frequency of CAs formed was observed with these three DRCs. However, performing three different biological dosimetry assays simultaneously on PB from five donors nonetheless results in variation in the frequency of CAs formed, especially at doses of 50 mGy or less, highlighting the difficulty of biological dosimetry using these methods. We conclude that it might be difficult to construct universal DRCs. … (more)
- Is Part Of:
- Journal of radiation research. Volume 59:Number 1(2018:Jan.)
- Journal:
- Journal of radiation research
- Issue:
- Volume 59:Number 1(2018:Jan.)
- Issue Display:
- Volume 59, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 59
- Issue:
- 1
- Issue Sort Value:
- 2018-0059-0001-0000
- Page Start:
- 35
- Page End:
- 42
- Publication Date:
- 2017-10-13
- Subjects:
- dicentric chromosome -- chromosome translocation -- dose–response curve -- biological dosimetry -- Giemsa staining -- centromere-FISH
Radiology, Medical -- Periodicals
Radiobiology -- Periodicals
Radiation -- Periodicals
616.0757 - Journal URLs:
- http://bibpurl.oclc.org/web/15847 ↗
http://bibpurl.oclc.org/web/7828 ↗
http://www.journalarchive.jst.go.jp/english/jnltop_en.php?cdjournal=jrr1960 ↗
https://www.jstage.jst.go.jp/browse/jrr ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/jrr/rrx052 ↗
- Languages:
- English
- ISSNs:
- 0449-3060
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16695.xml