An improved 96 well plate format lipid quantification assay for standardisation of experiments with extracellular vesicles. Issue 1 (29th January 2019)
- Record Type:
- Journal Article
- Title:
- An improved 96 well plate format lipid quantification assay for standardisation of experiments with extracellular vesicles. Issue 1 (29th January 2019)
- Main Title:
- An improved 96 well plate format lipid quantification assay for standardisation of experiments with extracellular vesicles
- Authors:
- Visnovitz, Tamás
Osteikoetxea, Xabier
Sódar, Barbara W.
Mihály, Judith
Lőrincz, Péter
Vukman, Krisztina V.
Tóth, Eszter Ágnes
Koncz, Anna
Székács, Inna
Horváth, Robert
Varga, Zoltán
Buzás, Edit I. - Abstract:
- ABSTRACT: The field of extracellular vesicles (EVs) is an exponentially growing segment of biomedical sciences. However, the problems of normalisation and quantification of EV samples have not been completely solved. Currently, EV samples are standardised on the basis of their protein content sometimes combined with determination of the particle number. However, even this combined approach may result in inaccuracy and overestimation of the EV concentration. Lipid bilayers are indispensable components of EVs. Therefore, a lipid‐based quantification, in combination with the determination of particle count and/or protein content, appears to be a straightforward and logical approach for the EV field. In this study, we set the goal to improve the previously reported sulfo‐phospho‐vanillin (SPV) lipid assay. We introduced an aqueous phase liposome standard (DOPC) to replace the purified lipid standards in organic solvents (used commonly in previous studies). Furthermore, we optimised the concentration of the vanillin reagent in the assay. We found that elimination of organic solvents from the reaction mixture could abolish the background colour that interfered with the assay. Comparison of the optimised assay with a commercial lipid kit (based on the original SPV lipid assay) showed an increase of sensitivity by approximately one order of magnitude. Thus, here we report a quick, reliable and sensitive test that may fill an existing gap in EV standardisation. When using theABSTRACT: The field of extracellular vesicles (EVs) is an exponentially growing segment of biomedical sciences. However, the problems of normalisation and quantification of EV samples have not been completely solved. Currently, EV samples are standardised on the basis of their protein content sometimes combined with determination of the particle number. However, even this combined approach may result in inaccuracy and overestimation of the EV concentration. Lipid bilayers are indispensable components of EVs. Therefore, a lipid‐based quantification, in combination with the determination of particle count and/or protein content, appears to be a straightforward and logical approach for the EV field. In this study, we set the goal to improve the previously reported sulfo‐phospho‐vanillin (SPV) lipid assay. We introduced an aqueous phase liposome standard (DOPC) to replace the purified lipid standards in organic solvents (used commonly in previous studies). Furthermore, we optimised the concentration of the vanillin reagent in the assay. We found that elimination of organic solvents from the reaction mixture could abolish the background colour that interfered with the assay. Comparison of the optimised assay with a commercial lipid kit (based on the original SPV lipid assay) showed an increase of sensitivity by approximately one order of magnitude. Thus, here we report a quick, reliable and sensitive test that may fill an existing gap in EV standardisation. When using the optimised lipid assay reported here, EV lipid measurements can be more reliable than protein‐based measurements. Furthermore, this novel assay is almost as sensitive and as easy as measuring proteins with a simple BCA test. … (more)
- Is Part Of:
- Journal of extracellular vesicles. Volume 8:Issue 1(2019)
- Journal:
- Journal of extracellular vesicles
- Issue:
- Volume 8:Issue 1(2019)
- Issue Display:
- Volume 8, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2019-0008-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-01-29
- Subjects:
- EV -- standardisation -- lipid assay -- sulfo‐phospho‐vanillin (SPV) reaction -- liposome standard -- exosomes -- microvesicles -- apoptotic bodies -- large oncosomes -- normalisation and quantification
Cells -- Mechanical properties -- Periodicals
Transport Vesicles
Cells -- Mechanical properties
Periodicals
Fulltext
Internet Resources
Periodicals
Electronic journals
Periodicals
571.63 - Journal URLs:
- http://www.ncbi.nlm.nih.gov/pmc/journals/2180/ ↗
https://www.tandfonline.com/toc/zjev20/current ↗
https://onlinelibrary.wiley.com/journal/20013078 ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/20013078.2019.1565263 ↗
- Languages:
- English
- ISSNs:
- 2001-3078
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16684.xml