Comparison of microscopic illumination between a three-dimensional heads-up system and eyepiece in cataract surgery. Issue 4 (July 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of microscopic illumination between a three-dimensional heads-up system and eyepiece in cataract surgery. Issue 4 (July 2021)
- Main Title:
- Comparison of microscopic illumination between a three-dimensional heads-up system and eyepiece in cataract surgery
- Authors:
- Nariai, Yui
Horiguchi, Masayuki
Mizuguchi, Tadashi
Sakurai, Ryota
Tanikawa, Atsuhiro - Abstract:
- Introduction: The ability to reduce illumination levels is generally accepted as one of the main benefits of a three-dimensional heads-up system (3D system: Ngenuity®; Alcon, CA, USA). Some studies have focused on illumination reduction in vitreoretinal procedures; however, information regarding illumination reduction in cataract surgery has not been published. Purpose: This study aimed to compare the illumination of the operational field with a 3D system and a standard microscope eyepiece during cataract surgery. Subject and methods: We retrospectively evaluated 91 eyes of 84 consecutive patients who were undergoing cataract surgery at our hospital. We used the 3D system and the eyepiece on alternative days. We determined the minimum light intensity required for safe surgery using the foot switch of the microscope (OMS800; Topcon, Tokyo, Japan). Illuminance on the ocular surface and the minimum illuminance required for the operation were calculated from the minimum light intensity. Results: The 3D system was used in 45 eyes (3D group), and the eyepiece was used in 46 eyes (eyepiece group). The values of minimum illuminance in the 3D group were significantly lower than those in the eyepiece group (3D: 5500 ± 2000 lux, eyepiece: 11, 900 ± 1800 lux; p < 0.001*). In addition, the illuminance of the operational field was reduced by 60.4% on average using the 3D system. Conclusion: With real-time digital processing and automated brightness control, the 3D system reduced ocularIntroduction: The ability to reduce illumination levels is generally accepted as one of the main benefits of a three-dimensional heads-up system (3D system: Ngenuity®; Alcon, CA, USA). Some studies have focused on illumination reduction in vitreoretinal procedures; however, information regarding illumination reduction in cataract surgery has not been published. Purpose: This study aimed to compare the illumination of the operational field with a 3D system and a standard microscope eyepiece during cataract surgery. Subject and methods: We retrospectively evaluated 91 eyes of 84 consecutive patients who were undergoing cataract surgery at our hospital. We used the 3D system and the eyepiece on alternative days. We determined the minimum light intensity required for safe surgery using the foot switch of the microscope (OMS800; Topcon, Tokyo, Japan). Illuminance on the ocular surface and the minimum illuminance required for the operation were calculated from the minimum light intensity. Results: The 3D system was used in 45 eyes (3D group), and the eyepiece was used in 46 eyes (eyepiece group). The values of minimum illuminance in the 3D group were significantly lower than those in the eyepiece group (3D: 5500 ± 2000 lux, eyepiece: 11, 900 ± 1800 lux; p < 0.001*). In addition, the illuminance of the operational field was reduced by 60.4% on average using the 3D system. Conclusion: With real-time digital processing and automated brightness control, the 3D system reduced ocular surface illumination by 50% or more. Hence, the 3D system may contribute to reducing the risk of retinal phototoxicity and patient photophobia. … (more)
- Is Part Of:
- European journal of ophthalmology. Volume 31:Issue 4(2021)
- Journal:
- European journal of ophthalmology
- Issue:
- Volume 31:Issue 4(2021)
- Issue Display:
- Volume 31, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 31
- Issue:
- 4
- Issue Sort Value:
- 2021-0031-0004-0000
- Page Start:
- 1817
- Page End:
- 1821
- Publication Date:
- 2021-07
- Subjects:
- 3D heads-up system -- cataract surgery phacoemulsification -- illumination -- Ngenuity®
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
617.7005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://www.eur-j-ophthalmol.com/Home/Index ↗
http://journals.sagepub.com/home/ejo ↗ - DOI:
- 10.1177/1120672120929962 ↗
- Languages:
- English
- ISSNs:
- 1120-6721
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16679.xml