Automated refraction after trifocal and trifocal toric intraocular lens implantation. Issue 3 (May 2021)
- Record Type:
- Journal Article
- Title:
- Automated refraction after trifocal and trifocal toric intraocular lens implantation. Issue 3 (May 2021)
- Main Title:
- Automated refraction after trifocal and trifocal toric intraocular lens implantation
- Authors:
- Rementería-Capelo, Laureano A
García-Pérez, Jorge L
Contreras, Inés
Blázquez, Vanesa
Ruiz-Alcocer, Javier - Abstract:
- Background: To analyze the correlation between automated refraction and manifest refraction after implantation of a trifocal intraocular lens or its toric version. Methods: This cross-sectional study involved 105 eyes of 105 patients. Subjects were divided in two groups: 62 with trifocal (AcrySof PanOptix) and 43 with trifocal toric (AcrySof PanOptix Toric) intraocular lenses. Automated refraction was employed as starting point for obtaining the manifest refraction. Automated refraction and manifest refraction measurements were analyzed and compared using the vector analysis 3 months after the surgery. Results: In both groups, the higher differences between automated refraction and manifest refraction measurements were found for the cylinder and the spherical equivalent (M). Cylinder values for PanOptix were: −0.60 ± 0.36 D with automated refraction and −0.17 ± 38 D with manifest refraction ( p < 0.001); for PanOptix Toric, the values were: −0.49 ± 0.31 D with automated refraction and −0.05 ± 0.21 D with manifest refraction ( p < 0.001). M values for PanOptix were: −0.23 ± 0.31 D with automated refraction and −0.03 ± 0.16 D with manifest refraction ( p < 0.001); for PanOptix Toric, the values were: −0.13 ± 0.40 D with automated refraction and 0.01 ± 0.12 D with manifest refraction ( p < 0.001). For the PanOptix group, intraclass correlation coefficients were: 0.51 (sphere), 0.64 (cylinder), 0.42 (M), 0.62 (J0), and 0.37 (J45). For the PanOptix Toric group, the intraclassBackground: To analyze the correlation between automated refraction and manifest refraction after implantation of a trifocal intraocular lens or its toric version. Methods: This cross-sectional study involved 105 eyes of 105 patients. Subjects were divided in two groups: 62 with trifocal (AcrySof PanOptix) and 43 with trifocal toric (AcrySof PanOptix Toric) intraocular lenses. Automated refraction was employed as starting point for obtaining the manifest refraction. Automated refraction and manifest refraction measurements were analyzed and compared using the vector analysis 3 months after the surgery. Results: In both groups, the higher differences between automated refraction and manifest refraction measurements were found for the cylinder and the spherical equivalent (M). Cylinder values for PanOptix were: −0.60 ± 0.36 D with automated refraction and −0.17 ± 38 D with manifest refraction ( p < 0.001); for PanOptix Toric, the values were: −0.49 ± 0.31 D with automated refraction and −0.05 ± 0.21 D with manifest refraction ( p < 0.001). M values for PanOptix were: −0.23 ± 0.31 D with automated refraction and −0.03 ± 0.16 D with manifest refraction ( p < 0.001); for PanOptix Toric, the values were: −0.13 ± 0.40 D with automated refraction and 0.01 ± 0.12 D with manifest refraction ( p < 0.001). For the PanOptix group, intraclass correlation coefficients were: 0.51 (sphere), 0.64 (cylinder), 0.42 (M), 0.62 (J0), and 0.37 (J45). For the PanOptix Toric group, the intraclass correlation coefficients were: 0.39 (sphere), 0.61 (cylinder), 0.39 (M), 0.53 (J0), and 0.09 (J45). Conclusion: The results of this study suggest that patients implanted with the trifocal and the trifocal toric intraocular lens under study showed similar automated refraction results between them, with a slight trend to more negative amounts of cylinder and M. Nevertheless, clinicians should carefully confirm all parameters of the refraction with manifest refraction. … (more)
- Is Part Of:
- European journal of ophthalmology. Volume 31:Issue 3(2021)
- Journal:
- European journal of ophthalmology
- Issue:
- Volume 31:Issue 3(2021)
- Issue Display:
- Volume 31, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 31
- Issue:
- 3
- Issue Sort Value:
- 2021-0031-0003-0000
- Page Start:
- 1031
- Page End:
- 1038
- Publication Date:
- 2021-05
- Subjects:
- Intraocular lens -- optics -- refraction -- instruments -- biometry -- axial length -- clinical tests -- intraocular lens calculation for primary -- secondary intraocular lens
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
617.7005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://www.eur-j-ophthalmol.com/Home/Index ↗
http://journals.sagepub.com/home/ejo ↗ - DOI:
- 10.1177/1120672120914848 ↗
- Languages:
- English
- ISSNs:
- 1120-6721
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16675.xml