Development of a minipig physical phantom from CT data. (28th July 2017)
- Record Type:
- Journal Article
- Title:
- Development of a minipig physical phantom from CT data. (28th July 2017)
- Main Title:
- Development of a minipig physical phantom from CT data
- Authors:
- Park, Sooyeun
Lee, Pilsoo
Ha, Wi-Ho
Kim, Han Sung
Park, Byeong Ryong
Kim, Jae Seok
Shim, Sehwan
Park, Sunhoo
Kim, Young-su
Kim, Chan Hyeong
Jin, Young-Woo - Abstract:
- ABSTRACT: Quantification of pathological progression of radiation-induced injury is essential in development of treatment methods, and a proper animal model is necessary for relevant radiological and medical studies. A minipig is a current animal model selected because of its similarities to humans in anatomy and pathology. In the present study, a minipig physical phantom was developed using computed tomography (CT) data. For dosimetry purposes, the minipig physical phantom was constructed on a slice-by-slice basis, with an array of holes to accommodate dosimeters. The phantom is constituted of three major organs, i.e. bone, lung, and remaining soft tissue, and the organs are clearly distinguishable on each 20-mm-thick axial slice. The quality of the tissue-equivalent (TE) substitutes was analyzed in terms of the atomic compositions and Hounsfield units (HUs). The density (in g/cm 3 ) and effective atomic number of TE substitutes for the bone, lung, and soft tissue are 1.4 and 7.9, 0.5 and 10.0, and 1.0 and 5.9, respectively. Although the TE substitutes have slightly different physical properties, we think the phantom is acceptable because the HU values of the TE substitutes lie in the HU range of real tissues.
- Is Part Of:
- Journal of radiation research. Volume 58:Number 5(2017:Sep.)
- Journal:
- Journal of radiation research
- Issue:
- Volume 58:Number 5(2017:Sep.)
- Issue Display:
- Volume 58, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 58
- Issue:
- 5
- Issue Sort Value:
- 2017-0058-0005-0000
- Page Start:
- 755
- Page End:
- 760
- Publication Date:
- 2017-07-28
- Subjects:
- minipig -- physical phantom -- tissue-equivalent material -- radiation dosimetry -- minipig physical phantom
Radiology, Medical -- Periodicals
Radiobiology -- Periodicals
Radiation -- Periodicals
616.0757 - Journal URLs:
- http://bibpurl.oclc.org/web/15847 ↗
http://bibpurl.oclc.org/web/7828 ↗
http://www.journalarchive.jst.go.jp/english/jnltop_en.php?cdjournal=jrr1960 ↗
https://www.jstage.jst.go.jp/browse/jrr ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/jrr/rrx036 ↗
- Languages:
- English
- ISSNs:
- 0449-3060
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16616.xml