Determining malignancy in CT guided fine needle aspirate biopsy of subsolid lung nodules: Is core biopsy necessary?. (2019)
- Record Type:
- Journal Article
- Title:
- Determining malignancy in CT guided fine needle aspirate biopsy of subsolid lung nodules: Is core biopsy necessary?. (2019)
- Main Title:
- Determining malignancy in CT guided fine needle aspirate biopsy of subsolid lung nodules: Is core biopsy necessary?
- Authors:
- Kiranantawat, Nantaka
McDermott, Shaunagh
Petranovic, Milena
Mino-Kenudson, Mari
Muniappan, Ashok
Sharma, Amita
Shepard, Jo-Anne O.
Digumarthy, Subba R. - Abstract:
- Highlights: CT-guided fine needle aspirate is accurate in the diagnoses of subsolid nodules. CT-guided fine needle aspirate of subsolid nodules is safe. A core needle biopsy is not always necessary. Abstract: Purpose: To assess the success of determining malignancy in subsolid lung nodules by fine needle aspirate of CT-guided transthoracic needle biopsy. Material and method: This IRB approved retrospective study analyzed CTguided transthoracic needle biopsy of 86 consecutive subsolid nodules (size 25 + 14 mm; Age 71 + 10 years: M: F, 27:59), with ground glass opacity of = 50% in 64 (74%) and size < 2 cm in 38 (44%). Fine needle aspirate was performed in all and additional core biopsy in 21 (24%). The biopsy results were correlated with resected surgical pathology in 59 (69%) and by long term clinical and imaging follow-up in 27 (31%). The statistical analysis was performed by Fischer exact test to determine the success rate in < 2cm and =2cm nodules and those with <50% and =50% ground glass opacity. Results: The technical success of performing the biopsy was 94.7%. The sensitivity for making a diagnosis of malignancy in small and large subsolid nodules was 88.6 and 95.6% (p=>0.05), with a specificity 100% in both groups. Core biopsy altered the diagnosis only in 1/21 (4.8%). The nondiagnostic biopsy rate was 18 and 11% for lesions with =50% and <50% ground glass opacity (p=>0.05). The incidence of pneumothorax was 21%, none requiring chest tube, and mild hemoptysis in 8%.Highlights: CT-guided fine needle aspirate is accurate in the diagnoses of subsolid nodules. CT-guided fine needle aspirate of subsolid nodules is safe. A core needle biopsy is not always necessary. Abstract: Purpose: To assess the success of determining malignancy in subsolid lung nodules by fine needle aspirate of CT-guided transthoracic needle biopsy. Material and method: This IRB approved retrospective study analyzed CTguided transthoracic needle biopsy of 86 consecutive subsolid nodules (size 25 + 14 mm; Age 71 + 10 years: M: F, 27:59), with ground glass opacity of = 50% in 64 (74%) and size < 2 cm in 38 (44%). Fine needle aspirate was performed in all and additional core biopsy in 21 (24%). The biopsy results were correlated with resected surgical pathology in 59 (69%) and by long term clinical and imaging follow-up in 27 (31%). The statistical analysis was performed by Fischer exact test to determine the success rate in < 2cm and =2cm nodules and those with <50% and =50% ground glass opacity. Results: The technical success of performing the biopsy was 94.7%. The sensitivity for making a diagnosis of malignancy in small and large subsolid nodules was 88.6 and 95.6% (p=>0.05), with a specificity 100% in both groups. Core biopsy altered the diagnosis only in 1/21 (4.8%). The nondiagnostic biopsy rate was 18 and 11% for lesions with =50% and <50% ground glass opacity (p=>0.05). The incidence of pneumothorax was 21%, none requiring chest tube, and mild hemoptysis in 8%. Conclusion: CT-guided transthoracic needle biopsy of both small and large subsolid nodules is highly sensitive and very specific for making the diagnosis of malignancy with a low rate of complications. Additional core biopsy offered no significant advantage over fine needle aspirate biopsy alone. … (more)
- Is Part Of:
- European journal of radiology open. Volume 6(2019)
- Journal:
- European journal of radiology open
- Issue:
- Volume 6(2019)
- Issue Display:
- Volume 6, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 6
- Issue:
- 2019
- Issue Sort Value:
- 2019-0006-2019-0000
- Page Start:
- 175
- Page End:
- 181
- Publication Date:
- 2019
- Subjects:
- CT guided lung biopsy -- Subsolid nodule -- Fine needle aspirate -- Core biopsy -- Lung cancer -- Ground glass opacity
Medical radiology -- Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23520477/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ejro.2019.04.006 ↗
- Languages:
- English
- ISSNs:
- 2352-0477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16625.xml