Antigen detection as a point-of-care test for TB: the case of lipoarabinomannan. (May 2012)
- Record Type:
- Journal Article
- Title:
- Antigen detection as a point-of-care test for TB: the case of lipoarabinomannan. (May 2012)
- Main Title:
- Antigen detection as a point-of-care test for TB: the case of lipoarabinomannan
- Authors:
- Swaminathan, Soumya
Rekha, VV Banu - Abstract:
- Evaluation of: Lawn SD, Kerkhoff AD, Vogt M, Wood R. Diagnostic accuracy of a low-cost, urine antigen, point-of-care screening assay for HIV-associated pulmonary tuberculosis before antiretroviral therapy: a descriptive study. Lancet Infect. Dis. 12(3), 201–209 (2011). The limitations of sputum smear microscopy, routine chest radiology for HIV-associated TB and culture-based diagnosis are well recognized, especially in resource-limited settings. The diagnostic accuracy of a new point-of-care lateral-flow urine strip test for lipoarabinomannan (Determine ® TB-LAM; Alere, MA, USA), which costs US$3.50 per test strip and provides results within 30 min, was evaluated in a cohort of South African patients for HIV-associated TB before starting anti-retroviral therapy in South Africa. Prevalence of culture-positive TB cases was 17.4%, among which 28.2% had sputum smear positivity. Determine ® TB-LAM (Alere, MA, USA) had highest sensitivity at low CD4 cell counts: 66.7, 51.7 and 39.0% at <50 cells, <100 cells and <200 cells per µl, respectively; specificity was greater than 98% for all strata. There was an incremental sensitivity when Determine TB-LAM was combined with smear microscopy, which did not differ statistically from the sensitivities obtained by testing a single sputum sample with the Xpert ® MTB/RIF (Cepheid; CA, USA) assay. Determine TB-LAM is a simple, low-cost alternative to existing diagnostic assays for TB screening in HIV-infected patients with very low CD4 + cellEvaluation of: Lawn SD, Kerkhoff AD, Vogt M, Wood R. Diagnostic accuracy of a low-cost, urine antigen, point-of-care screening assay for HIV-associated pulmonary tuberculosis before antiretroviral therapy: a descriptive study. Lancet Infect. Dis. 12(3), 201–209 (2011). The limitations of sputum smear microscopy, routine chest radiology for HIV-associated TB and culture-based diagnosis are well recognized, especially in resource-limited settings. The diagnostic accuracy of a new point-of-care lateral-flow urine strip test for lipoarabinomannan (Determine ® TB-LAM; Alere, MA, USA), which costs US$3.50 per test strip and provides results within 30 min, was evaluated in a cohort of South African patients for HIV-associated TB before starting anti-retroviral therapy in South Africa. Prevalence of culture-positive TB cases was 17.4%, among which 28.2% had sputum smear positivity. Determine ® TB-LAM (Alere, MA, USA) had highest sensitivity at low CD4 cell counts: 66.7, 51.7 and 39.0% at <50 cells, <100 cells and <200 cells per µl, respectively; specificity was greater than 98% for all strata. There was an incremental sensitivity when Determine TB-LAM was combined with smear microscopy, which did not differ statistically from the sensitivities obtained by testing a single sputum sample with the Xpert ® MTB/RIF (Cepheid; CA, USA) assay. Determine TB-LAM is a simple, low-cost alternative to existing diagnostic assays for TB screening in HIV-infected patients with very low CD4 + cell counts. … (more)
- Is Part Of:
- Future microbiology. Volume 7:Number 5(2012)
- Journal:
- Future microbiology
- Issue:
- Volume 7:Number 5(2012)
- Issue Display:
- Volume 7, Issue 5 (2012)
- Year:
- 2012
- Volume:
- 7
- Issue:
- 5
- Issue Sort Value:
- 2012-0007-0005-0000
- Page Start:
- 559
- Page End:
- 564
- Publication Date:
- 2012-05
- Subjects:
- Determine® TB-LAM -- HIV-TB -- TB antigen -- TB diagnosis -- urine LAM
Microbiology -- Research -- Periodicals
616.9041 - Journal URLs:
- http://www.futuremedicine.com/loi/fmb ↗
http://www.futuremedicine.com/ ↗ - DOI:
- 10.2217/fmb.12.34 ↗
- Languages:
- English
- ISSNs:
- 1746-0913
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4060.604000
British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 16648.xml