Design and clinical use of a rotational phantom for dosimetric verification of IMRT/VMAT treatments. (June 2018)
- Record Type:
- Journal Article
- Title:
- Design and clinical use of a rotational phantom for dosimetric verification of IMRT/VMAT treatments. (June 2018)
- Main Title:
- Design and clinical use of a rotational phantom for dosimetric verification of IMRT/VMAT treatments
- Authors:
- Grams, Michael P.
de los Santos, Luis E. Fong - Abstract:
- Highlights: QA, especially for SBRT/SRS cases, benefits from film's high spatial resolution. Most QA methods are limited to measurements in the coronal or sagittal planes. A rotatable cylindrical phantom allows for film measurements in any plane. Film allows true composite measurements without the angular corrections for arrays. Abstract: Purpose: To describe the design and clinical use of a rotational phantom for dosimetric verification of IMRT/VMAT treatment plans using radiochromic film. Methods: A solid water cylindrical phantom was designed with separable upper and lower halves and rests on plastic bearings allowing for 360° rotation about its central axis. The phantom accommodates a half sheet of radiochromic film, and by rotating the cylinder, the film can be placed in any plane between coronal and sagittal. Calculated dose planes coinciding with rotated film measurements are exported by rotating the CT image and dose distribution within the treatment planning system. The process is illustrated with 2 rotated film measurements of an SRS treatment plan involving 4 separate targets. Additionally, 276 patient specific QA measurements were obtained with the phantom and analyzed with a 2%/2 mm gamma criterion. Results: The average 2%/2 mm gamma passing rate for all 276 plans was 99.3%. Seventy-two of the 276 plans were measured with the plane of the film rotated between the coronal and sagittal planes and had an average passing rate of 99.4%. Conclusions: The rotationalHighlights: QA, especially for SBRT/SRS cases, benefits from film's high spatial resolution. Most QA methods are limited to measurements in the coronal or sagittal planes. A rotatable cylindrical phantom allows for film measurements in any plane. Film allows true composite measurements without the angular corrections for arrays. Abstract: Purpose: To describe the design and clinical use of a rotational phantom for dosimetric verification of IMRT/VMAT treatment plans using radiochromic film. Methods: A solid water cylindrical phantom was designed with separable upper and lower halves and rests on plastic bearings allowing for 360° rotation about its central axis. The phantom accommodates a half sheet of radiochromic film, and by rotating the cylinder, the film can be placed in any plane between coronal and sagittal. Calculated dose planes coinciding with rotated film measurements are exported by rotating the CT image and dose distribution within the treatment planning system. The process is illustrated with 2 rotated film measurements of an SRS treatment plan involving 4 separate targets. Additionally, 276 patient specific QA measurements were obtained with the phantom and analyzed with a 2%/2 mm gamma criterion. Results: The average 2%/2 mm gamma passing rate for all 276 plans was 99.3%. Seventy-two of the 276 plans were measured with the plane of the film rotated between the coronal and sagittal planes and had an average passing rate of 99.4%. Conclusions: The rotational phantom allows for accurate film measurements in any plane. With this technique, regions of a dose distribution which might otherwise require multiple sagittal or coronal measurements can be verified with as few as a single measurement. This increases efficiency and, in combination with the high spatial resolution inherent to film dosimetry, makes the rotational technique an attractive option for patient-specific QA. … (more)
- Is Part Of:
- Physica medica. Volume 50(2018)
- Journal:
- Physica medica
- Issue:
- Volume 50(2018)
- Issue Display:
- Volume 50, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 50
- Issue:
- 2018
- Issue Sort Value:
- 2018-0050-2018-0000
- Page Start:
- 59
- Page End:
- 65
- Publication Date:
- 2018-06
- Subjects:
- Gafchromic film dosimetry -- SRS -- Rotational phantom
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.05.019 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16634.xml