Visual outcomes and patient satisfaction 3 and 12 months after implantation of a refractive rotationally asymmetric multifocal intraocular lens. Issue 5 (May 2017)
- Record Type:
- Journal Article
- Title:
- Visual outcomes and patient satisfaction 3 and 12 months after implantation of a refractive rotationally asymmetric multifocal intraocular lens. Issue 5 (May 2017)
- Main Title:
- Visual outcomes and patient satisfaction 3 and 12 months after implantation of a refractive rotationally asymmetric multifocal intraocular lens
- Authors:
- McNeely, Richard N.
Pazo, Eric
Spence, Andrew
Richoz, Olivier
Nesbit, Andrew M.
Moore, Tara C.B.
Moore, Jonathan E. - Abstract:
- Abstract : Purpose : To assess the 3‐month and 12‐month postoperative visual performance and subjective patient satisfaction after refractive lens exchange (RLE) with implantation of a rotationally asymmetric multifocal intraocular lens (IOL). Setting : Cathedral Eye Clinic, Belfast, United Kingdom. Design : Prospective case series. Methods : The refraction, uncorrected (UDVA) and corrected distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance‐corrected intermediate and near visual acuities, and a quality of vision (QoV) questionnaire were evaluated 3 months and 12 months after implantation of an SBL‐3 IOL. Results : The study enrolled 100 eyes of 50 patients. The mean monocular UDVA was −0.02 logarithm of minimum angle of resolution (logMAR) ± 0.12 (SD) 3 months postoperatively and −0.01 ± 0.10 logMAR at 12 months ( P = .393). The mean monocular UIVA was 0.39 ± 0.11 logMAR and 0.41 ± 0.12 logMAR, respectively ( P = .06). The mean monocular UNVA was 0.12 ± 0.13 logMAR and 0.14 ± 0.12 logMAR, respectively ( P = .077). The mean QoV score was 8.26 ± 1.16 at 3 months with a significant improvement at 12 months, at which time the mean QoV score was 8.84 ± 1.08 ( P ≤ .001). Conclusions : This asymmetric multifocal IOL provided excellent unaided vision with no significant difference in near, intermediate, and distance vision 3 months and 12 months postoperatively. However, there was a significant improvement in subjective outcomes atAbstract : Purpose : To assess the 3‐month and 12‐month postoperative visual performance and subjective patient satisfaction after refractive lens exchange (RLE) with implantation of a rotationally asymmetric multifocal intraocular lens (IOL). Setting : Cathedral Eye Clinic, Belfast, United Kingdom. Design : Prospective case series. Methods : The refraction, uncorrected (UDVA) and corrected distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance‐corrected intermediate and near visual acuities, and a quality of vision (QoV) questionnaire were evaluated 3 months and 12 months after implantation of an SBL‐3 IOL. Results : The study enrolled 100 eyes of 50 patients. The mean monocular UDVA was −0.02 logarithm of minimum angle of resolution (logMAR) ± 0.12 (SD) 3 months postoperatively and −0.01 ± 0.10 logMAR at 12 months ( P = .393). The mean monocular UIVA was 0.39 ± 0.11 logMAR and 0.41 ± 0.12 logMAR, respectively ( P = .06). The mean monocular UNVA was 0.12 ± 0.13 logMAR and 0.14 ± 0.12 logMAR, respectively ( P = .077). The mean QoV score was 8.26 ± 1.16 at 3 months with a significant improvement at 12 months, at which time the mean QoV score was 8.84 ± 1.08 ( P ≤ .001). Conclusions : This asymmetric multifocal IOL provided excellent unaided vision with no significant difference in near, intermediate, and distance vision 3 months and 12 months postoperatively. However, there was a significant improvement in subjective outcomes at the second postoperative assessment, during which patients reported a significantly better QoV score and less blurred vision. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 43:Issue 5(2017)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 43:Issue 5(2017)
- Issue Display:
- Volume 43, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 43
- Issue:
- 5
- Issue Sort Value:
- 2017-0043-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-05
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2017.01.025 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16623.xml