Intraindividual comparative analysis of capsule opacification after implantation of 2 single‐piece hydrophobic acrylic intraocular lenses models: Three‐year follow‐up. Issue 5 (May 2015)
- Record Type:
- Journal Article
- Title:
- Intraindividual comparative analysis of capsule opacification after implantation of 2 single‐piece hydrophobic acrylic intraocular lenses models: Three‐year follow‐up. Issue 5 (May 2015)
- Main Title:
- Intraindividual comparative analysis of capsule opacification after implantation of 2 single‐piece hydrophobic acrylic intraocular lenses models: Three‐year follow‐up
- Authors:
- Kahraman, Guenal
Amon, Michael
Ferdinaro, Clara
Nigl, Karl
Walch, Michael - Abstract:
- Abstract : Purpose : To compare the 3‐year postoperative anterior (ACO) and posterior (PCO) capsule opacification and the level of anterior capsule retraction after implantation of 2 single‐piece hydrophobic acrylic intraocular lens (IOL) models. Setting : Hospital of St. John of God, Vienna, Austria. Design : Comparative randomized controlled double‐blind clinical trial. Methods : Eyes with bilateral cataract were evaluated. Each patient had an Acrysof SA60AT (interrupted optic edge) IOL implanted in 1 eye (Group A) and a Tecnis ZCB00 (continuous optic edge) IOL implanted in the fellow eye (Group B). One and 3 years postoperatively, PCO was evaluated using Evaluation of Posterior Capsule Opacification software and the ACO level and capsule‐retraction level were evaluated and graded subjectively. Results : The study evaluated 100 eyes of 50 patients ranging from 61 to 80 years. Postoperatively, there were no statistically significant differences in PCO between Group A and Group B at 1 year (0.06 ± 0.12 [SD] and 0.07 ± 0.13, respectively; P = 4.35) or 3 years (0.23 ± 0.36 and 0.22 ± 0.32, respectively; P = .66). In Group A and Group B, ACO was present in 18.0% of eyes and 2.7% of eyes, respectively, at 1 year ( P = .03) and in 92.0% and 24.0%, respectively, at 3 years ( P < .01). Capsule phimosis (18.0% at 1 year; 30.0% at 3 years) and glistenings (66.0% at 1 year; 86.0% at 3 years) were observed in Group A only. Conclusion : Both IOLs had similarly low PCO rates 3 yearsAbstract : Purpose : To compare the 3‐year postoperative anterior (ACO) and posterior (PCO) capsule opacification and the level of anterior capsule retraction after implantation of 2 single‐piece hydrophobic acrylic intraocular lens (IOL) models. Setting : Hospital of St. John of God, Vienna, Austria. Design : Comparative randomized controlled double‐blind clinical trial. Methods : Eyes with bilateral cataract were evaluated. Each patient had an Acrysof SA60AT (interrupted optic edge) IOL implanted in 1 eye (Group A) and a Tecnis ZCB00 (continuous optic edge) IOL implanted in the fellow eye (Group B). One and 3 years postoperatively, PCO was evaluated using Evaluation of Posterior Capsule Opacification software and the ACO level and capsule‐retraction level were evaluated and graded subjectively. Results : The study evaluated 100 eyes of 50 patients ranging from 61 to 80 years. Postoperatively, there were no statistically significant differences in PCO between Group A and Group B at 1 year (0.06 ± 0.12 [SD] and 0.07 ± 0.13, respectively; P = 4.35) or 3 years (0.23 ± 0.36 and 0.22 ± 0.32, respectively; P = .66). In Group A and Group B, ACO was present in 18.0% of eyes and 2.7% of eyes, respectively, at 1 year ( P = .03) and in 92.0% and 24.0%, respectively, at 3 years ( P < .01). Capsule phimosis (18.0% at 1 year; 30.0% at 3 years) and glistenings (66.0% at 1 year; 86.0% at 3 years) were observed in Group A only. Conclusion : Both IOLs had similarly low PCO rates 3 years postoperatively, although more ACO and capsule retraction were observed in eyes with the interrupted optic edge IOL. Financial Disclosure : No author has a financial or proprietary interest in any material or method mentioned. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 41:Issue 5(2015)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 41:Issue 5(2015)
- Issue Display:
- Volume 41, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 41
- Issue:
- 5
- Issue Sort Value:
- 2015-0041-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-05
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2014.07.041 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16649.xml