Third‐ and fourth‐generation formulas for intraocular lens power calculation before and after phakic intraocular lens insertion in high myopia. Issue 11 (November 2018)
- Record Type:
- Journal Article
- Title:
- Third‐ and fourth‐generation formulas for intraocular lens power calculation before and after phakic intraocular lens insertion in high myopia. Issue 11 (November 2018)
- Main Title:
- Third‐ and fourth‐generation formulas for intraocular lens power calculation before and after phakic intraocular lens insertion in high myopia
- Authors:
- Amro, Mazen
Chanbour, Wassef
Arej, Nicolas
Jarade, Elias - Abstract:
- Abstract : Purpose : To determine the effect of Visian Implantable Collamer Lens phakic intraocular lens (pIOL) insertion on biometric parameters and IOL power calculation. Setting : Beirut Eye and ENT Specialist Hospital, Beirut, Lebanon. Design : Prospective case series. Methods : The IOLMaster 500 biometer was used to measure axial length (AL), keratometry (K), and anterior chamber depth (ACD) values before and 2 months after pIOL implantation. The IOL power was calculated using third‐generation formulas (SRK/T, Holladay 1, Hoffer Q) and fourth‐generation formulas (Haigis, Barrett Universal II). Results : The study comprised 24 eyes (12 patients). The preoperative and postoperative AL were comparable (27.35 mm ± 1.51 [SD] versus 27.36 ± 1.6 mm; P = .91), as were the K values. There was a significant difference between the preoperative and postoperative ACD (3.67 ± 0.46 mm versus 3.4 ± 0.56 mm; P = .008). The mean IOL power calculation did not change significantly using the Haigis (10.04 ± 3.42 diopters [D] versus 10.1 ± 3.59 D; P = .69), SRK/T (9.85 ± 3.41 D versus 9.94 ± 3.58 D; P = .44), Holladay 1 (9.70 ± 3.47 D versus 9.80 ± 3.64 D; P = .45), Hoffer Q (9.70 ± 3.40 D versus 9.85 ± 3.59 D; P = .37), or Barrett Universal II (9.29 ± 3.52 D versus 9.35 ± 3.71 D; P = .63) formula. Conclusions : Phakic IOL insertion did not affect IOL power calculation. If preoperative data are not available, postoperative values can be used in IOL calculation formulas.
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 44:Issue 11(2018)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 44:Issue 11(2018)
- Issue Display:
- Volume 44, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 44
- Issue:
- 11
- Issue Sort Value:
- 2018-0044-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-11
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2018.07.053 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16645.xml