Evaluation of intraocular lens position during phacoemulsification using intraoperative spectral‐domain optical coherence tomography. Issue 5 (May 2016)
- Record Type:
- Journal Article
- Title:
- Evaluation of intraocular lens position during phacoemulsification using intraoperative spectral‐domain optical coherence tomography. Issue 5 (May 2016)
- Main Title:
- Evaluation of intraocular lens position during phacoemulsification using intraoperative spectral‐domain optical coherence tomography
- Authors:
- Lytvynchuk, Lyubomyr M.
Glittenberg, Carl G.
Falkner‐Radler, Christiane I.
Neumaier‐Ammerer, Beatrix
Smretschnig, Eva
Hagen, Stefan
Ansari‐Shahrezaei, Siamak
Binder, Susanne - Abstract:
- Abstract : Purpose : To assess the position of intraocular lenses (IOLs) at the end of standard phacoemulsification with intraoperative spectral‐domain optical coherence tomography (SD‐OCT). Settings : Department of Ophthalmology, Rudolf Foundation Hospital, Vienna, Austria. Design : Prospective case series. Methods : Standard phacoemulsification with IOL implantation was performed. The Rescan 700 SD‐OCT system was used for intraoperative imaging. The anterior segment of the eye was scanned using SD‐OCT at the end of the surgery. The distance from the IOL optic center and the IOL optic edge to the posterior capsule was measured postoperatively using graphic software. Results : The study comprised 74 patients (101 eyes). The mean axial length was 23.97 mm (range 21.43 to 28.61 mm). The mean IOL power was 20.39 diopters (D) (range 6.5 to 27.5 D). Contact between the IOL and posterior capsule was absent in 88 cases (87.13%), and partial or full contact was present in 13 cases (12.87%). The mean distance between the IOL central optic and posterior capsule was 0.71 pixel (range 0.06 to 1.38 pixels) in 99 cases (98.02%). In 42 cases (57.53%), partial contact between the IOL edges and the posterior capsule was noticed. The mean distance between the IOL edge and posterior capsule was 0.21 pixel (range 0.04 to 0.92 pixel). Conclusions : Intraoperative SD‐OCT facilitated the imaging of IOL position during standard phacoemulsification. Contact between the IOL central optic andAbstract : Purpose : To assess the position of intraocular lenses (IOLs) at the end of standard phacoemulsification with intraoperative spectral‐domain optical coherence tomography (SD‐OCT). Settings : Department of Ophthalmology, Rudolf Foundation Hospital, Vienna, Austria. Design : Prospective case series. Methods : Standard phacoemulsification with IOL implantation was performed. The Rescan 700 SD‐OCT system was used for intraoperative imaging. The anterior segment of the eye was scanned using SD‐OCT at the end of the surgery. The distance from the IOL optic center and the IOL optic edge to the posterior capsule was measured postoperatively using graphic software. Results : The study comprised 74 patients (101 eyes). The mean axial length was 23.97 mm (range 21.43 to 28.61 mm). The mean IOL power was 20.39 diopters (D) (range 6.5 to 27.5 D). Contact between the IOL and posterior capsule was absent in 88 cases (87.13%), and partial or full contact was present in 13 cases (12.87%). The mean distance between the IOL central optic and posterior capsule was 0.71 pixel (range 0.06 to 1.38 pixels) in 99 cases (98.02%). In 42 cases (57.53%), partial contact between the IOL edges and the posterior capsule was noticed. The mean distance between the IOL edge and posterior capsule was 0.21 pixel (range 0.04 to 0.92 pixel). Conclusions : Intraoperative SD‐OCT facilitated the imaging of IOL position during standard phacoemulsification. Contact between the IOL central optic and posterior capsule at the end of the surgery occurred rarely. Improved IOL design should be considered. Financial Disclosure : Drs. Binder and Glittenberg are consultants to Carl Zeiss Meditech AG. None of the other authors has a financial or proprietary interest in any material or method mentioned. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 42:Issue 5(2016)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 42:Issue 5(2016)
- Issue Display:
- Volume 42, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 42
- Issue:
- 5
- Issue Sort Value:
- 2016-0042-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-05
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2016.01.044 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16661.xml