Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses. Issue 12 (December 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses. Issue 12 (December 2016)
- Main Title:
- Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses
- Authors:
- McNeely, Richard N.
Pazo, Eric
Spence, Andrew
Richoz, Olivier
Nesbit, Andrew M.
Moore, Tara C.B.
Moore, Jonathan E. - Abstract:
- Abstract : Purpose : To compare the postoperative quality of vision between different bilateral placements of near segments of rotationally asymmetric refractive multifocal intraocular lenses (IOLs) and to determine how this affects visual performance. Setting : Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. Design : Retrospective comparative case series. Methods : The study enrolled consecutive patients having refractive lens exchange and implantation of rotationally asymmetric multifocal IOLs. Group 1 received bilateral SBL‐3 IOLs and Group 2 received bilateral Lentis Mplus LS‐312 MF30 IOLs, with the near segments placed inferonasally in each group. Group 3 received a Lentis Mplus LS‐312 MF20 IOL in the dominant eye with the near segment positioned superotemporal and a Lenstec SBL‐3 IOL positioned inferonasally in the fellow eye. Binocular uncorrected (UDVA) and corrected distance visual acuities, binocular uncorrected near (UNVA) and intermediate (UIVA) visual acuities, binocular distance‐corrected near and intermediate visual acuities, and quality of vision were evaluated over 3 months postoperatively. Results : The study enrolled 180 patients (360 eyes). There was no significant difference between the groups in binocular UDVA, UIVA, and UNVA; however, there was a significant difference between the groups in quality of vision ( P ≤ .001). Group 3 had significantly better overall quality of vision. Conclusion : When implanting rotationally asymmetricAbstract : Purpose : To compare the postoperative quality of vision between different bilateral placements of near segments of rotationally asymmetric refractive multifocal intraocular lenses (IOLs) and to determine how this affects visual performance. Setting : Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. Design : Retrospective comparative case series. Methods : The study enrolled consecutive patients having refractive lens exchange and implantation of rotationally asymmetric multifocal IOLs. Group 1 received bilateral SBL‐3 IOLs and Group 2 received bilateral Lentis Mplus LS‐312 MF30 IOLs, with the near segments placed inferonasally in each group. Group 3 received a Lentis Mplus LS‐312 MF20 IOL in the dominant eye with the near segment positioned superotemporal and a Lenstec SBL‐3 IOL positioned inferonasally in the fellow eye. Binocular uncorrected (UDVA) and corrected distance visual acuities, binocular uncorrected near (UNVA) and intermediate (UIVA) visual acuities, binocular distance‐corrected near and intermediate visual acuities, and quality of vision were evaluated over 3 months postoperatively. Results : The study enrolled 180 patients (360 eyes). There was no significant difference between the groups in binocular UDVA, UIVA, and UNVA; however, there was a significant difference between the groups in quality of vision ( P ≤ .001). Group 3 had significantly better overall quality of vision. Conclusion : When implanting rotationally asymmetric multifocal IOLs, a combination of superotemporal placement of the near segment (+2.00 diopter [D] addition [add]) in the dominant eye with inferonasal placement of the near segment (+3.00 D add) in the fellow eye yielded consistent, high overall quality of vision and uncorrected visual acuity. Financial Disclosure : None of the authors has a financial or proprietary interest in any material or method mentioned. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 42:Issue 12(2016)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 42:Issue 12(2016)
- Issue Display:
- Volume 42, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 42
- Issue:
- 12
- Issue Sort Value:
- 2016-0042-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-12
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2016.10.016 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16634.xml