Intraocular lens power calculation in eyes with extreme myopia: Comparison of Barrett Universal II, Haigis, and Olsen formulas. Issue 6 (June 2019)
- Record Type:
- Journal Article
- Title:
- Intraocular lens power calculation in eyes with extreme myopia: Comparison of Barrett Universal II, Haigis, and Olsen formulas. Issue 6 (June 2019)
- Main Title:
- Intraocular lens power calculation in eyes with extreme myopia: Comparison of Barrett Universal II, Haigis, and Olsen formulas
- Authors:
- Rong, Xianfang
He, Wenwen
Zhu, Qian
Qian, Dongjin
Lu, Yi
Zhu, Xiangjia - Abstract:
- Abstract : Purpose : To compare the accuracy of the Barrett Universal II, Haigis, and Olsen formulas in calculating intraocular lens (IOL) power in eyes with extreme myopia. Setting : Eye and Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China. Design : Prospective case series. Methods : Eyes were divided into 3 axial length (AL) groups as follows: 26.0 to 28.0 mm (control), 28.0 to 30.0 mm (extreme myopia 1), and 30.0 mm or more (extreme myopia 2). The mean error (ME) 1 month postoperatively was adjusted to zero by optimizing the lens factor; then, the median absolute errors (MedAEs) were compared between formulas. Factors associated with postoperative refractive errors were analyzed. Results : After optimization, the MEs of the Barrett Universal II, Haigis, and Olsen formulas were 0.04 diopter (D) ± 0.48 (SD), 0.04 ± 0.66 D, and 0.04 ± 0.52 D, respectively, and the MedAEs were 0.37 D, 0.46 D, and 0.39 D, respectively ( P = .044; Haigis versus Barrett: P = .038). In the extreme myopia 1 group, all 3 formulas produced small MedAEs ( P = .662). In the extreme myopia 2 group, the Haigis formula produced a significantly greater MedAE than the Barrett Universal II formula ( P = .007; Haigis versus Olsen: P = .055). The accuracy of the Haigis formula in myopic eyes was affected by the AL and keratometry value, whereas the accuracy of the Barrett Universal II and Olsen formulas was affected by the AL only. Conclusions : In eyes with an AL of 28.0 to 30.0 mm, all 3Abstract : Purpose : To compare the accuracy of the Barrett Universal II, Haigis, and Olsen formulas in calculating intraocular lens (IOL) power in eyes with extreme myopia. Setting : Eye and Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China. Design : Prospective case series. Methods : Eyes were divided into 3 axial length (AL) groups as follows: 26.0 to 28.0 mm (control), 28.0 to 30.0 mm (extreme myopia 1), and 30.0 mm or more (extreme myopia 2). The mean error (ME) 1 month postoperatively was adjusted to zero by optimizing the lens factor; then, the median absolute errors (MedAEs) were compared between formulas. Factors associated with postoperative refractive errors were analyzed. Results : After optimization, the MEs of the Barrett Universal II, Haigis, and Olsen formulas were 0.04 diopter (D) ± 0.48 (SD), 0.04 ± 0.66 D, and 0.04 ± 0.52 D, respectively, and the MedAEs were 0.37 D, 0.46 D, and 0.39 D, respectively ( P = .044; Haigis versus Barrett: P = .038). In the extreme myopia 1 group, all 3 formulas produced small MedAEs ( P = .662). In the extreme myopia 2 group, the Haigis formula produced a significantly greater MedAE than the Barrett Universal II formula ( P = .007; Haigis versus Olsen: P = .055). The accuracy of the Haigis formula in myopic eyes was affected by the AL and keratometry value, whereas the accuracy of the Barrett Universal II and Olsen formulas was affected by the AL only. Conclusions : In eyes with an AL of 28.0 to 30.0 mm, all 3 formulas were accurate. In eyes with AL of 30.0 mm or more, the Barrett Universal II formula was better than the Haigis formula, possibly because there were fewer influencing factors. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 45:Issue 6(2019)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 45:Issue 6(2019)
- Issue Display:
- Volume 45, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 45
- Issue:
- 6
- Issue Sort Value:
- 2019-0045-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-06
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2018.12.025 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16669.xml