Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in short eyes. Issue 6 (June 2019)
- Record Type:
- Journal Article
- Title:
- Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in short eyes. Issue 6 (June 2019)
- Main Title:
- Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in short eyes
- Authors:
- Sudhakar, Shruti
Hill, Darren C.
King, Tonya S.
Scott, Ingrid U.
Mishra, Gautam
Ernst, Brett B.
Pantanelli, Seth M. - Abstract:
- Abstract : Purpose : To compare the accuracy of preoperative biometry‐based formulas to intraoperative aberrometry (IA) with respect to predicting refractive outcomes after cataract surgery in short eyes. Setting : Private practice and community‐based ambulatory surgery center. Design : Retrospective consecutive case series. Methods : Eyes with an axial length (AL) shorter than 22.1 mm underwent cataract extraction and intraocular lens (IOL) implantation. The predicted residual refractive error was calculated preoperatively using Hoffer Q, Holladay 2, Haigis, Barrett Universal II, and Hill‐RBF formulas and intraoperatively using IA. The postoperative spherical equivalent (SE) was compared with the predicted SE to evaluate the accuracy of each aforementioned method. Results : Fifty‐one eyes from 38 patients met criteria to be included in the analysis. Without optimizing the formulas specifically for short eyes, the mean numerical errors (MNEs) associated with Hoffer Q, Holladay 2, Haigis, Barrett Universal II, Hill‐RBF, and IA were −0.08 (95% confidence interval [CI], −0.30 to 0.13), −0.14 (95% CI, −0.35 to 0.07), +0.26 (95% CI, 0.05 to 0.47), +0.11 (95% CI, −0.10 to 0.32), +0.07 (95% CI, −0.14 to 0.28), and +0.00 (95% CI, −0.21 to 0.21), respectively ( P < .001). The proportion of eyes within ±0.5 diopter (D) of the predicted SE were 49.0%, 43.1%, 52.9%, 52.9%, 60.8%, and 58.8%, respectively ( P = .06). The prediction outcomes from IA were statistically better than Haigis,Abstract : Purpose : To compare the accuracy of preoperative biometry‐based formulas to intraoperative aberrometry (IA) with respect to predicting refractive outcomes after cataract surgery in short eyes. Setting : Private practice and community‐based ambulatory surgery center. Design : Retrospective consecutive case series. Methods : Eyes with an axial length (AL) shorter than 22.1 mm underwent cataract extraction and intraocular lens (IOL) implantation. The predicted residual refractive error was calculated preoperatively using Hoffer Q, Holladay 2, Haigis, Barrett Universal II, and Hill‐RBF formulas and intraoperatively using IA. The postoperative spherical equivalent (SE) was compared with the predicted SE to evaluate the accuracy of each aforementioned method. Results : Fifty‐one eyes from 38 patients met criteria to be included in the analysis. Without optimizing the formulas specifically for short eyes, the mean numerical errors (MNEs) associated with Hoffer Q, Holladay 2, Haigis, Barrett Universal II, Hill‐RBF, and IA were −0.08 (95% confidence interval [CI], −0.30 to 0.13), −0.14 (95% CI, −0.35 to 0.07), +0.26 (95% CI, 0.05 to 0.47), +0.11 (95% CI, −0.10 to 0.32), +0.07 (95% CI, −0.14 to 0.28), and +0.00 (95% CI, −0.21 to 0.21), respectively ( P < .001). The proportion of eyes within ±0.5 diopter (D) of the predicted SE were 49.0%, 43.1%, 52.9%, 52.9%, 60.8%, and 58.8%, respectively ( P = .06). The prediction outcomes from IA were statistically better than Haigis, but not other formulas. When formula and IA predictions differed by 0.5 D or more, IA's ability to recommend a more emmetropic outcome was no better than chance (50%). Conclusions : Intraoperative aberrometry is not significantly different from the best preoperative biometry‐based methods available for IOL power selection in short eyes. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 45:Issue 6(2019)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 45:Issue 6(2019)
- Issue Display:
- Volume 45, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 45
- Issue:
- 6
- Issue Sort Value:
- 2019-0045-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-06
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2018.12.016 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16669.xml