- Effect of tear osmolarity on repeatability of keratometry for cataract surgery planning
- Authors:
- Epitropoulos, Alice T.
Matossian, Cynthia
Berdy, Gregg J.
Malhotra, Ranjan P.
Potvin, Richard - Abstract:
- Abstract : Purpose : To evaluate the effects of tear osmolarity on the repeatability of keratometry (K) measurements in patients presenting for cataract surgery. Setting : Three clinical practices. Design : Observational prospective nonrandomized study. Methods : Subjects were prospectively recruited based on tear osmolarity (Tearlab Osmolarity System); that is, osmolarity more than 316 mOsm/L in at least 1 eye (hyperosmolar) and osmolarity less than 308 mOsm/L in both eyes (normal). The baseline K value was measured, and a second measurement was taken on the same instrument (IOLMaster) within 3 weeks of the first. Variability in average K, calculated corneal astigmatism using vector analysis, and intraocular lens (IOL) sphere power calculations were compared between groups. Results : The hyperosmolar group (50 subjects) had a statistically significantly higher variability in the average K reading ( P = .05) than the normal group (25 subjects) and a statistically significantly higher percentage of eyes with a 1.0 diopter (D) or greater difference in the measured corneal astigmatism ( P = .02). A statistically significantly higher percentage of eyes in the hyperosmolar group had an IOL power difference of more than 0.5 D ( P = .02). No statistically significant differences were present when the subjects were grouped by self‐reported dry eye. Conclusions : Significantly more variability in average K and anterior corneal astigmatism was observed in the hyperosmolar group, withAbstract : Purpose : To evaluate the effects of tear osmolarity on the repeatability of keratometry (K) measurements in patients presenting for cataract surgery. Setting : Three clinical practices. Design : Observational prospective nonrandomized study. Methods : Subjects were prospectively recruited based on tear osmolarity (Tearlab Osmolarity System); that is, osmolarity more than 316 mOsm/L in at least 1 eye (hyperosmolar) and osmolarity less than 308 mOsm/L in both eyes (normal). The baseline K value was measured, and a second measurement was taken on the same instrument (IOLMaster) within 3 weeks of the first. Variability in average K, calculated corneal astigmatism using vector analysis, and intraocular lens (IOL) sphere power calculations were compared between groups. Results : The hyperosmolar group (50 subjects) had a statistically significantly higher variability in the average K reading ( P = .05) than the normal group (25 subjects) and a statistically significantly higher percentage of eyes with a 1.0 diopter (D) or greater difference in the measured corneal astigmatism ( P = .02). A statistically significantly higher percentage of eyes in the hyperosmolar group had an IOL power difference of more than 0.5 D ( P = .02). No statistically significant differences were present when the subjects were grouped by self‐reported dry eye. Conclusions : Significantly more variability in average K and anterior corneal astigmatism was observed in the hyperosmolar group, with significant resultant differences in IOL power calculations. Variability was not significantly different when subjects were grouped by self‐reported dry eye. Measurement of tear osmolarity at the time of cataract surgery planning can effectively identify patients with a higher likelihood of high unexpected refractive error resulting from inaccurate keratometry. Financial Disclosure : Drs. Epitropoulos, Matossian, Berdy, and Malhotra received compensation from Tearlab for participating in the study. No author has a financial or proprietary interest in any material or method mentioned. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 41:Issue 8(2015)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 41:Issue 8(2015)
- Issue Display:
- Volume 41, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 41
- Issue:
- 8
- Issue Sort Value:
- 2015-0041-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-08
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2015.01.016 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16633.xml