Demarcation line depth after contact lens–assisted corneal crosslinking for progressive keratoconus: Comparison of dextran‐based and hydroxypropyl methylcellulose–based riboflavin solutions. Issue 10 (October 2017)
- Record Type:
- Journal Article
- Title:
- Demarcation line depth after contact lens–assisted corneal crosslinking for progressive keratoconus: Comparison of dextran‐based and hydroxypropyl methylcellulose–based riboflavin solutions. Issue 10 (October 2017)
- Main Title:
- Demarcation line depth after contact lens–assisted corneal crosslinking for progressive keratoconus: Comparison of dextran‐based and hydroxypropyl methylcellulose–based riboflavin solutions
- Authors:
- Malhotra, Chintan
Jain, Arun K.
Gupta, Amit
Ram, Jagat
Ramatchandirane, Balamurugan
Dhingra, Deepika
Sachdeva, Kulbhushan
Kumar, Amit - Abstract:
- Abstract : Purpose : To compare the demarcation line depth after contact lens–assisted corneal crosslinking (CXL) for progressive keratoconus using dextran‐based and hydroxypropyl methylcellulose (HPMC)‐based riboflavin solutions. Setting : Advanced Eye Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India. Design : Retrospective case series. Methods : Patients with preoperative epithelium‐on (epi‐on) minimum corneal thickness between 350 μm and 450 μm having contact lens–assisted CXL for progressive keratoconus were crosslinked with isoosmolar 0.1% riboflavin in 20% dextran 500 or HPMC 1.1%. The primary outcome measure was the mean demarcation line depth measured 1 month postoperatively on anterior‐segment optical coherence tomography. The secondary outcome measure was change in endothelial cell density (ECD) 6 months from baseline. Results : The study comprised 21 patients (21 eyes, 9 in the HPMC group and 12 in the dextran group). The mean demarcation line depth was deeper in the HPMC group (308.22 μm ± 84.19 [SD]) than in the dextran group (235.33 ± 64.87 μm) ( P < .04). This difference remained significant ( P = .02) even after controlling for the preoperative lesser epi‐on minimum corneal thickness in the HPMC group (385.56 ±13.81 μm) versus the dextran group (413.08 ± 29.58 μm) ( P < .02). The ECD 6 months after contact lens–assisted CXL was comparable to the baseline levels in both groups ( P = .19 and P = .09, respectively). ConclusionAbstract : Purpose : To compare the demarcation line depth after contact lens–assisted corneal crosslinking (CXL) for progressive keratoconus using dextran‐based and hydroxypropyl methylcellulose (HPMC)‐based riboflavin solutions. Setting : Advanced Eye Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India. Design : Retrospective case series. Methods : Patients with preoperative epithelium‐on (epi‐on) minimum corneal thickness between 350 μm and 450 μm having contact lens–assisted CXL for progressive keratoconus were crosslinked with isoosmolar 0.1% riboflavin in 20% dextran 500 or HPMC 1.1%. The primary outcome measure was the mean demarcation line depth measured 1 month postoperatively on anterior‐segment optical coherence tomography. The secondary outcome measure was change in endothelial cell density (ECD) 6 months from baseline. Results : The study comprised 21 patients (21 eyes, 9 in the HPMC group and 12 in the dextran group). The mean demarcation line depth was deeper in the HPMC group (308.22 μm ± 84.19 [SD]) than in the dextran group (235.33 ± 64.87 μm) ( P < .04). This difference remained significant ( P = .02) even after controlling for the preoperative lesser epi‐on minimum corneal thickness in the HPMC group (385.56 ±13.81 μm) versus the dextran group (413.08 ± 29.58 μm) ( P < .02). The ECD 6 months after contact lens–assisted CXL was comparable to the baseline levels in both groups ( P = .19 and P = .09, respectively). Conclusion : During contact lens–assisted CXL, HPMC‐based riboflavin seemed to be associated with a deeper demarcation line than dextran‐based riboflavin, although both solutions were safe for the endothelium at 6 months. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 43:Issue 10(2017)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 43:Issue 10(2017)
- Issue Display:
- Volume 43, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 43
- Issue:
- 10
- Issue Sort Value:
- 2017-0043-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-10
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2017.07.032 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16659.xml