Evaluation of the small‐aperture intracorneal inlay: Three‐year results from the cohort of the U.S. Food and Drug Administration clinical trial. Issue 5 (May 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation of the small‐aperture intracorneal inlay: Three‐year results from the cohort of the U.S. Food and Drug Administration clinical trial. Issue 5 (May 2018)
- Main Title:
- Evaluation of the small‐aperture intracorneal inlay: Three‐year results from the cohort of the U.S. Food and Drug Administration clinical trial
- Authors:
- Vukich, John A.
Durrie, Daniel S.
Pepose, Jay S.
Thompson, Vance
van de Pol, Corina
Lin, Ling - Abstract:
- Abstract : Purpose : To evaluate the safety and effectiveness of the Kamra small‐aperture intracorneal inlay. Setting : Centers in North America, Europe, Asia, and Australia. Design : Prospective clinical trial. Methods : Patients with emmetropic presbyopia had intracorneal implantation of the inlay in the nondominant eye. Results : The study comprised 507 patients with emmetropic presbyopia who were aged 45 to 60 years old. The implanted eyes exhibited 3.5 diopters of defocus range above 20/40, with 363 (87.1%) of 417 patients and 391 (93.8%) of 417 patients having 20/40 or better monocular and binocular uncorrected near visual acuity (UNVA) at 36 months, respectively. Patients implanted via a femtosecond laser pocket procedure using a spot/line setting of 6 μm × 6 μm demonstrated further improved near vision, with 131 (90.3%) of 145 patients and 137 (94.5%) of 145 of patients having 20/40 or better monocular and binocular UNVA, respectively. Uncorrected distance visual acuity 20/25 or better was maintained in 135 (93.1%) of 145 of implanted eyes and 100% (145) of 145 of implanted eyes binocularly at 36 months. Less than 1.5% of eyes had a loss of 2 or more lines of corrected distance visual acuity for 3 months or more at any time after surgery. Forty‐four inlays (8.7%) were removed from the full cohort over 3 years. The removal rate was significantly less in the 6 × 6 pocket group (3.0% for visual complaints) and further reduced with deeper implantation (0%). Less thanAbstract : Purpose : To evaluate the safety and effectiveness of the Kamra small‐aperture intracorneal inlay. Setting : Centers in North America, Europe, Asia, and Australia. Design : Prospective clinical trial. Methods : Patients with emmetropic presbyopia had intracorneal implantation of the inlay in the nondominant eye. Results : The study comprised 507 patients with emmetropic presbyopia who were aged 45 to 60 years old. The implanted eyes exhibited 3.5 diopters of defocus range above 20/40, with 363 (87.1%) of 417 patients and 391 (93.8%) of 417 patients having 20/40 or better monocular and binocular uncorrected near visual acuity (UNVA) at 36 months, respectively. Patients implanted via a femtosecond laser pocket procedure using a spot/line setting of 6 μm × 6 μm demonstrated further improved near vision, with 131 (90.3%) of 145 patients and 137 (94.5%) of 145 of patients having 20/40 or better monocular and binocular UNVA, respectively. Uncorrected distance visual acuity 20/25 or better was maintained in 135 (93.1%) of 145 of implanted eyes and 100% (145) of 145 of implanted eyes binocularly at 36 months. Less than 1.5% of eyes had a loss of 2 or more lines of corrected distance visual acuity for 3 months or more at any time after surgery. Forty‐four inlays (8.7%) were removed from the full cohort over 3 years. The removal rate was significantly less in the 6 × 6 pocket group (3.0% for visual complaints) and further reduced with deeper implantation (0%). Less than 1.0% of the patients reported severe glare or halos postoperatively. Conclusion : The small‐aperture corneal inlay was found to be safe and effective, improving near vision both monocularly and binocularly with minimal effect on distance visual acuity. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 44:Issue 5(2018)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 44:Issue 5(2018)
- Issue Display:
- Volume 44, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 44
- Issue:
- 5
- Issue Sort Value:
- 2018-0044-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-05
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2018.02.023 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16662.xml