Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery. Issue 3 (January 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery. Issue 3 (January 2017)
- Main Title:
- Comparison of the performance and safety of 2 ophthalmic viscosurgical devices in cataract surgery
- Authors:
- Auffarth, Gerd U.
Auerbach, Florian N.
Rabsilber, Tanja
Gegúndez, José A.
Cuiña, Ricardo
Renard, Yves
Vinciguerra, Paolo
Camesasca, Fabrizio
Van Cauwenberge, Francoise
Amzallag, Thierry
Van Setten, Gysbert
Holzer, Mike P. - Abstract:
- Abstract : Purpose : To compare the clinical performance and safety of 2 ophthalmic viscosurgical devices (OVDs)—Twinvisc (OVD 1) and Duovisc (OVD 2)—in cataract surgery. Setting : European multicenter study. Design : Prospective randomized controlled study. Methods : Patients with cataract had phacoemulsification and intraocular lens implantation in 1 eye. They were randomly assigned to receive OVD 1 or OVD 2. Preoperative and postoperative examinations over 3 months included mean intraocular pressure (IOP), incidence of IOP peaks (≥30 mm Hg and ≥24 mm Hg), endothelial cell count (ECC), corneal thickness, and intraocular inflammation. A subjective evaluation of the OVDs was performed. Results : The study comprised 220 patients. The incidence of IOP peaks and the mean IOP were not statistically significantly different between the 2 groups at any of the follow‐up visits. At 6 hours, the incidence of IOP spikes 30 mm Hg or higher was 6.5% and 7.2% in the OVD 1 and the OVD 2 groups, respectively ( P = .846). For the IOP spikes 24 mm Hg or higher, the incidence was 16.8% and 25.2%, respectively ( P = .128). Three months postoperatively there was no statistically significant difference in ECC and pachymetry between the 2 groups. Mild inflammation was noticed up to 7 days postoperatively after which it resolved in both groups. Subjectively, the OVD 2 was easier to use, whereas the OVD 1 had better cohesive and dispersive properties. Conclusions : Both OVDs have similar performanceAbstract : Purpose : To compare the clinical performance and safety of 2 ophthalmic viscosurgical devices (OVDs)—Twinvisc (OVD 1) and Duovisc (OVD 2)—in cataract surgery. Setting : European multicenter study. Design : Prospective randomized controlled study. Methods : Patients with cataract had phacoemulsification and intraocular lens implantation in 1 eye. They were randomly assigned to receive OVD 1 or OVD 2. Preoperative and postoperative examinations over 3 months included mean intraocular pressure (IOP), incidence of IOP peaks (≥30 mm Hg and ≥24 mm Hg), endothelial cell count (ECC), corneal thickness, and intraocular inflammation. A subjective evaluation of the OVDs was performed. Results : The study comprised 220 patients. The incidence of IOP peaks and the mean IOP were not statistically significantly different between the 2 groups at any of the follow‐up visits. At 6 hours, the incidence of IOP spikes 30 mm Hg or higher was 6.5% and 7.2% in the OVD 1 and the OVD 2 groups, respectively ( P = .846). For the IOP spikes 24 mm Hg or higher, the incidence was 16.8% and 25.2%, respectively ( P = .128). Three months postoperatively there was no statistically significant difference in ECC and pachymetry between the 2 groups. Mild inflammation was noticed up to 7 days postoperatively after which it resolved in both groups. Subjectively, the OVD 2 was easier to use, whereas the OVD 1 had better cohesive and dispersive properties. Conclusions : Both OVDs have similar performance and safety profiles in phacoemulsification cataract surgery. No clinically relevant differences were found between the 2 devices regarding transient IOP spikes, mean IOP, corneal endothelium injury, or inflammation. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 41:Issue 3(2015)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 41:Issue 3(2015)
- Issue Display:
- Volume 41, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 41
- Issue:
- 3
- Issue Sort Value:
- 2015-0041-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-01
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2016.10.025 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16639.xml