Open‐capsule intraocular lens to prevent posterior capsule opacification. Issue 7 (July 2019)
- Record Type:
- Journal Article
- Title:
- Open‐capsule intraocular lens to prevent posterior capsule opacification. Issue 7 (July 2019)
- Main Title:
- Open‐capsule intraocular lens to prevent posterior capsule opacification
- Authors:
- Katsuki, Yoko
Matsushima, Hiroyuki
Mukai, Koichiro
Watabiki, Satoshi
Aose, Masamoto
Terauchi, Wataru
Nagamoto, Toshiyuki
Senoo, Tadashi - Abstract:
- Abstract : Purpose : To develop a single‐piece open‐capsule intraocular lens (IOL) that can be inserted through a small incision and that prevents posterior capsule opacification (PCO) by expanding the capsule and circulating aqueous humor into the capsular bag. Setting : Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan. Design : Experimental study. Method : Using the same hydrophobic acrylic material as the NY‐60 IOL, a prototype open‐capsule IOL was constructed. The IOL has a single optic and 2 haptics, with a 2.8 mm high spacer and holes through which aqueous humor circulates into the capsular bag by separating the anterior capsule from the posterior capsule and expanding the capsule. The open‐capsule IOL or NY‐60 (as a control group) was inserted in rabbit eyes. Posterior capsule opacification development was evaluated by measuring the thickness of the cell layer at the center of the posterior capsule on histopathologic specimens and statistically comparing the thickness between the open‐capsule IOL group and control group. Results : The open‐capsule IOL could be inserted through a 3.2 mm corneal incision using a D cartridge. The mean thickness of the cell layer at the center of the posterior capsule was 4.78 μm ± 2.61 (SD) in the open‐capsule IOL group and 101.14 ± 25.19 μm in the control group and was significantly smaller in the open‐capsule IOL group. Conclusion : The prototype single‐piece IOL could be implanted through a small incision andAbstract : Purpose : To develop a single‐piece open‐capsule intraocular lens (IOL) that can be inserted through a small incision and that prevents posterior capsule opacification (PCO) by expanding the capsule and circulating aqueous humor into the capsular bag. Setting : Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan. Design : Experimental study. Method : Using the same hydrophobic acrylic material as the NY‐60 IOL, a prototype open‐capsule IOL was constructed. The IOL has a single optic and 2 haptics, with a 2.8 mm high spacer and holes through which aqueous humor circulates into the capsular bag by separating the anterior capsule from the posterior capsule and expanding the capsule. The open‐capsule IOL or NY‐60 (as a control group) was inserted in rabbit eyes. Posterior capsule opacification development was evaluated by measuring the thickness of the cell layer at the center of the posterior capsule on histopathologic specimens and statistically comparing the thickness between the open‐capsule IOL group and control group. Results : The open‐capsule IOL could be inserted through a 3.2 mm corneal incision using a D cartridge. The mean thickness of the cell layer at the center of the posterior capsule was 4.78 μm ± 2.61 (SD) in the open‐capsule IOL group and 101.14 ± 25.19 μm in the control group and was significantly smaller in the open‐capsule IOL group. Conclusion : The prototype single‐piece IOL could be implanted through a small incision and prevented PCO by expanding the lens capsule and circulating aqueous humor into the capsular bag. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 45:Issue 7(2019)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 45:Issue 7(2019)
- Issue Display:
- Volume 45, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 45
- Issue:
- 7
- Issue Sort Value:
- 2019-0045-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-07
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2018.12.022 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16635.xml