Tracking boundary movement and exterior shape modelling in lung EIT imaging. (26th May 2015)
- Record Type:
- Journal Article
- Title:
- Tracking boundary movement and exterior shape modelling in lung EIT imaging. (26th May 2015)
- Main Title:
- Tracking boundary movement and exterior shape modelling in lung EIT imaging
- Authors:
- Biguri, A
Grychtol, B
Adler, A
Soleimani, M - Abstract:
- Abstract: Electrical impedance tomography (EIT) has shown significant promise for lung imaging. One key challenge for EIT in this application is the movement of electrodes during breathing, which introduces artefacts in reconstructed images. Various approaches have been proposed to compensate for electrode movement, but no comparison of these approaches is available. This paper analyses boundary model mismatch and electrode movement in lung EIT. The aim is to evaluate the extent to which various algorithms tolerate movement, and to determine if a patient specific model is required for EIT lung imaging. Movement data are simulated from a CT-based model, and image analysis is performed using quantitative figures of merit. The electrode movement is modelled based on expected values of chest movement and an extended Jacobian method is proposed to make use of exterior boundary tracking. Results show that a dynamical boundary tracking is the most robust method against any movement, but is computationally more expensive. Simultaneous electrode movement and conductivity reconstruction algorithms show increased robustness compared to only conductivity reconstruction. The results of this comparative study can help develop a better understanding of the impact of shape model mismatch and electrode movement in lung EIT.
- Is Part Of:
- Physiological measurement. Volume 36:Number 6(2015:Jun.)
- Journal:
- Physiological measurement
- Issue:
- Volume 36:Number 6(2015:Jun.)
- Issue Display:
- Volume 36, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 36
- Issue:
- 6
- Issue Sort Value:
- 2015-0036-0006-0000
- Page Start:
- 1119
- Page End:
- 1135
- Publication Date:
- 2015-05-26
- Subjects:
- electrode movement -- shape error -- electrical impedance tomography
Physiology -- Measurement -- Periodicals
Patient monitoring -- Periodicals
612 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0967-3334 ↗ - DOI:
- 10.1088/0967-3334/36/6/1119 ↗
- Languages:
- English
- ISSNs:
- 0967-3334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16617.xml