Enhancing clinically-relevant shoulder function assessment using only essential movements. (18th February 2015)
- Record Type:
- Journal Article
- Title:
- Enhancing clinically-relevant shoulder function assessment using only essential movements. (18th February 2015)
- Main Title:
- Enhancing clinically-relevant shoulder function assessment using only essential movements
- Authors:
- Pichonnaz, C
Lécureux, E
Bassin, J-P
Duc, C
Farron, A
Aminian, K
Jolles, B M
Gleeson, N - Abstract:
- Abstract: Kinematic functional evaluation with body-worn sensors provides discriminative and responsive scores after shoulder surgery, but the optimal movements' combination has not yet been scientifically investigated. The aim of this study was the development of a simplified shoulder function kinematic score including only essential movements. The P Score, a seven-movement kinematic score developed on 31 healthy participants and 35 patients before surgery and at 3, 6 and 12 months after shoulder surgery, served as a reference. Principal component analysis and multiple regression were used to create simplified scoring models. The candidate models were compared to the reference score. ROC curve for shoulder pathology detection and correlations with clinical questionnaires were calculated. The B–B Score (hand to the Back and hand upwards as to change a Bulb) showed no difference to the P Score in time*score interaction ( P > .05) and its relation with the reference score was highly linear ( R 2 > .97). Absolute value of correlations with clinical questionnaires ranged from 0.51 to 0.77. Sensitivity was 97% and specificity 94%. The B–B and reference scores are equivalent for the measurement of group responses. The validated simplified scoring model presents practical advantages that facilitate the objective evaluation of shoulder function in clinical practice.
- Is Part Of:
- Physiological measurement. Volume 36:Number 3(2015:Mar.)
- Journal:
- Physiological measurement
- Issue:
- Volume 36:Number 3(2015:Mar.)
- Issue Display:
- Volume 36, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 36
- Issue:
- 3
- Issue Sort Value:
- 2015-0036-0003-0000
- Page Start:
- 547
- Page End:
- 560
- Publication Date:
- 2015-02-18
- Subjects:
- shoulder -- outcome treatment -- body-worn sensors -- biomechanics -- validation studies as topic
Physiology -- Measurement -- Periodicals
Patient monitoring -- Periodicals
612 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0967-3334 ↗ - DOI:
- 10.1088/0967-3334/36/3/547 ↗
- Languages:
- English
- ISSNs:
- 0967-3334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16648.xml