Wang‐Koch formula for optimization of intraocular lens power calculation: Evaluation at a Canadian center. Issue 1 (January 2018)
- Record Type:
- Journal Article
- Title:
- Wang‐Koch formula for optimization of intraocular lens power calculation: Evaluation at a Canadian center. Issue 1 (January 2018)
- Main Title:
- Wang‐Koch formula for optimization of intraocular lens power calculation: Evaluation at a Canadian center
- Authors:
- Popovic, Marko
Schlenker, Matthew B.
Campos‐Möller, Xavier
Pereira, Austin
Ahmed, Iqbal Ike K. - Abstract:
- Abstract : Purpose : To externally validate the Wang‐Koch method for optimization of intraocular lens (IOL) formulas. Setting : TLC Laser Eye Centre, Mississauga, Ontario, Canada. Design : Retrospective case series. Methods : Consecutive cataract patients with an axial length (AL) of 25.0 mm or longer were recruited. The predicted postoperative spherical equivalents (SEs) calculated from the Holladay 1 formula were compared with the 3‐week postoperative SEs to yield prediction errors for Wang‐Koch adjusted and unadjusted ALs. A mixed linear model was used to compare the proportion of eyes with a prediction error of ±0.25 diopter (D) or worse, ±0.50 D or worse, and ±1.00 D or worse between groups. The secondary outcomes of mean absolute error and median absolute error were also analyzed. A subgroup analysis was performed based on AL subgroups. Results : Two hundred sixty‐two eyes were selected for inclusion with a balanced sex distribution, a mean age of 62.49 years ± 9.13 (SD), and a preoperative AL of 26.49 ± 1.10 mm. Subgroup prediction error comparisons of ±0.50 D or worse favored unadjusted eyes with ALs between 25.0 mm and 26.0 mm (n = 105; P < .001), no difference in eyes with ALs between 26.0 mm and 27.0 mm (n = 91; P = .43), adjusted eyes with ALs between 27.0 mm and 28.0 mm (n = 36; P = .003), and adjusted eyes with ALs of 28.00 mm or longer (n = 30; P < .001). Conclusion : The Wang‐Koch adjustment should only be applied in eyes with ALs longer than 27.0 mm thatAbstract : Purpose : To externally validate the Wang‐Koch method for optimization of intraocular lens (IOL) formulas. Setting : TLC Laser Eye Centre, Mississauga, Ontario, Canada. Design : Retrospective case series. Methods : Consecutive cataract patients with an axial length (AL) of 25.0 mm or longer were recruited. The predicted postoperative spherical equivalents (SEs) calculated from the Holladay 1 formula were compared with the 3‐week postoperative SEs to yield prediction errors for Wang‐Koch adjusted and unadjusted ALs. A mixed linear model was used to compare the proportion of eyes with a prediction error of ±0.25 diopter (D) or worse, ±0.50 D or worse, and ±1.00 D or worse between groups. The secondary outcomes of mean absolute error and median absolute error were also analyzed. A subgroup analysis was performed based on AL subgroups. Results : Two hundred sixty‐two eyes were selected for inclusion with a balanced sex distribution, a mean age of 62.49 years ± 9.13 (SD), and a preoperative AL of 26.49 ± 1.10 mm. Subgroup prediction error comparisons of ±0.50 D or worse favored unadjusted eyes with ALs between 25.0 mm and 26.0 mm (n = 105; P < .001), no difference in eyes with ALs between 26.0 mm and 27.0 mm (n = 91; P = .43), adjusted eyes with ALs between 27.0 mm and 28.0 mm (n = 36; P = .003), and adjusted eyes with ALs of 28.00 mm or longer (n = 30; P < .001). Conclusion : The Wang‐Koch adjustment should only be applied in eyes with ALs longer than 27.0 mm that have IOL power calculation with the Holladay 1 formula. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 44:Issue 1(2018)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 44:Issue 1(2018)
- Issue Display:
- Volume 44, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 44
- Issue:
- 1
- Issue Sort Value:
- 2018-0044-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-01
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2017.09.035 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16656.xml