Accuracy of SS‐OCT biometry compared with partial coherence interferometry biometry for combined phacovitrectomy with internal limiting membrane peeling. Issue 1 (January 2019)
- Record Type:
- Journal Article
- Title:
- Accuracy of SS‐OCT biometry compared with partial coherence interferometry biometry for combined phacovitrectomy with internal limiting membrane peeling. Issue 1 (January 2019)
- Main Title:
- Accuracy of SS‐OCT biometry compared with partial coherence interferometry biometry for combined phacovitrectomy with internal limiting membrane peeling
- Authors:
- Vounotrypidis, Efstathios
Haralanova, Velina
Muth, Daniel R.
Wertheimer, Christian
Shajari, Mehdi
Wolf, Armin
Priglinger, Siegfried
Mayer, Wolfgang J. - Abstract:
- Abstract : Purpose : To evaluate the accuracy of a swept‐source optical coherence tomography (SS‐OCT) biometer compared with a standard partial coherence interferometry (PCI) biometer in terms of phacovitrectomy for vitreomacular pathology and cataract. Setting : Department of Ophthalmology, Ludwig‐Maximilians‐University Munich, Germany. Design : Prospective, nonrandomized, single center consecutive case series. Methods : Patients with age‐related cataract, regular corneal astigmatism less than 1.25 diopters (D) and a clinically significant vitreomacular pathology (epiretinal membrane [ERM], macular hole, or vitreomacular traction [VMT] syndrome) who had combined phacovitrectomy with internal limiting membrane peeling were enrolled. Objective and manifest refraction, corrected distance visual acuity, SS‐OCT biometry, and PCI biometry were obtained preoperatively and 3 months postoperatively. The refractive prediction error and mean absolute error (MAE) were calculated for each biometric device with the Haigis formula. The percentage of eyes with a prediction error within ±0.50 D or less were calculated. Results : The study comprised 79 eyes of 79 patients. The mean refractive prediction error of all eyes was −0.27 D ± 0.76 (SD) for the PCI biometer and −0.28 ± 0.57 D for the SS‐OCT biometer ( P = .802), and the MAE was 0.61 ± 0.53 D and 0.46 ± 0.43 D, respectively ( P = .012). A prediction error within ±0.50 D or less was observed in 55 eyes (70%) with the SS‐OCT biometerAbstract : Purpose : To evaluate the accuracy of a swept‐source optical coherence tomography (SS‐OCT) biometer compared with a standard partial coherence interferometry (PCI) biometer in terms of phacovitrectomy for vitreomacular pathology and cataract. Setting : Department of Ophthalmology, Ludwig‐Maximilians‐University Munich, Germany. Design : Prospective, nonrandomized, single center consecutive case series. Methods : Patients with age‐related cataract, regular corneal astigmatism less than 1.25 diopters (D) and a clinically significant vitreomacular pathology (epiretinal membrane [ERM], macular hole, or vitreomacular traction [VMT] syndrome) who had combined phacovitrectomy with internal limiting membrane peeling were enrolled. Objective and manifest refraction, corrected distance visual acuity, SS‐OCT biometry, and PCI biometry were obtained preoperatively and 3 months postoperatively. The refractive prediction error and mean absolute error (MAE) were calculated for each biometric device with the Haigis formula. The percentage of eyes with a prediction error within ±0.50 D or less were calculated. Results : The study comprised 79 eyes of 79 patients. The mean refractive prediction error of all eyes was −0.27 D ± 0.76 (SD) for the PCI biometer and −0.28 ± 0.57 D for the SS‐OCT biometer ( P = .802), and the MAE was 0.61 ± 0.53 D and 0.46 ± 0.43 D, respectively ( P = .012). A prediction error within ±0.50 D or less was observed in 55 eyes (70%) with the SS‐OCT biometer compared with 42 eyes (53%) with the PCI biometer ( P = .0001). The MAE with the SS‐OCT biometer was statistically significantly lower in eyes with ERMs or macular holes compared with the PCI biometer ( P = .043 and P = .028, respectively), whereas no statistically significant difference was observed in eyes with VMT syndrome ( P = .286). Conclusions : The SS‐OCT biometer showed a statistically significant lower MAE compared with the PCI biometer, and it is recommended for precise intraocular lens power calculations in combined phacovitrectomy for cataract and vitreomacular diseases. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 45:Issue 1(2019)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 45:Issue 1(2019)
- Issue Display:
- Volume 45, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 45
- Issue:
- 1
- Issue Sort Value:
- 2019-0045-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-01
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2018.08.027 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16619.xml