Biometry with a new swept‐source optical coherence tomography biometer: Repeatability and agreement with an optical low‐coherence reflectometry device. Issue 4 (April 2016)
- Record Type:
- Journal Article
- Title:
- Biometry with a new swept‐source optical coherence tomography biometer: Repeatability and agreement with an optical low‐coherence reflectometry device. Issue 4 (April 2016)
- Main Title:
- Biometry with a new swept‐source optical coherence tomography biometer: Repeatability and agreement with an optical low‐coherence reflectometry device
- Authors:
- Kurian, Mathew
Negalur, Nikhil
Das, Sudeep
Puttaiah, Narendra K.
Haria, Dhawal
J, Tejal S.
Thakkar, Maithil M. - Abstract:
- Abstract : Purpose : To assess the repeatability of a new swept‐source optical coherence tomography (SS‐OCT) biometer (IOLMaster 700) and evaluate the agreement with an optical low‐coherence reflectometry (OLCR) biometer (Lenstar 900) in cataractous eyes. Setting : Tertiary eyecare facility. Design : Prospective evaluation of a diagnostic test. Methods : Eyes of patients had 3 consecutive scans acquired by the same operator. The repeatability of measurements was assessed using the within‐subject standard deviation and coefficient of variation (CoV). Agreement between the mean measurements of each machine was evaluated. Results : The study comprised 100 eyes of 100 patients. The median lens thickness and axial length (AL) measurements were significantly greater ( P < .001) with SS‐OCT (4.29 mm and 23.5 mm, respectively, versus 4.25 mm and 23.4 mm, respectively); anterior chamber depth (ACD) was greater with OLCR (2.72 mm versus 2.70 mm, respectively) ( P < .001). The within‐subject standard deviation and CoV of the AL (0.01 and 0.05, respectively) and the ACD (0.04 and 1.22, respectively) measurements showed lower variability with SS‐OCT (0.05 and 0.21, respectively, for AL; 0.06 and 1.99, respectively, for ACD) than with OLCR. Good agreement was seen for anterior segment measurements between the 2 devices. The 95% limits of agreement of most parameters fell within the test–retest variability of the parameters. The SS‐OCT biometer also showed better penetration in denseAbstract : Purpose : To assess the repeatability of a new swept‐source optical coherence tomography (SS‐OCT) biometer (IOLMaster 700) and evaluate the agreement with an optical low‐coherence reflectometry (OLCR) biometer (Lenstar 900) in cataractous eyes. Setting : Tertiary eyecare facility. Design : Prospective evaluation of a diagnostic test. Methods : Eyes of patients had 3 consecutive scans acquired by the same operator. The repeatability of measurements was assessed using the within‐subject standard deviation and coefficient of variation (CoV). Agreement between the mean measurements of each machine was evaluated. Results : The study comprised 100 eyes of 100 patients. The median lens thickness and axial length (AL) measurements were significantly greater ( P < .001) with SS‐OCT (4.29 mm and 23.5 mm, respectively, versus 4.25 mm and 23.4 mm, respectively); anterior chamber depth (ACD) was greater with OLCR (2.72 mm versus 2.70 mm, respectively) ( P < .001). The within‐subject standard deviation and CoV of the AL (0.01 and 0.05, respectively) and the ACD (0.04 and 1.22, respectively) measurements showed lower variability with SS‐OCT (0.05 and 0.21, respectively, for AL; 0.06 and 1.99, respectively, for ACD) than with OLCR. Good agreement was seen for anterior segment measurements between the 2 devices. The 95% limits of agreement of most parameters fell within the test–retest variability of the parameters. The SS‐OCT biometer also showed better penetration in dense posterior subcapsular cataracts, measuring AL successfully in 96% of cases. Conclusions : The new SS‐OCT biometer showed good repeatability and agreement with the OLCR biometer. The SS‐OCT biometer measured the AL with fewer dropouts compared with the OLCR even in dense cataracts. Financial Disclosure : None of the authors has a financial or proprietary interest in any material or method mentioned. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 42:Issue 4(2016)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 42:Issue 4(2016)
- Issue Display:
- Volume 42, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 42
- Issue:
- 4
- Issue Sort Value:
- 2016-0042-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-04
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2016.01.038 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16631.xml