Comparison of ocular aberrations measured by a Fourier‐based Hartmann‐Shack and Zernike‐based Tscherning aberrometer before and after laser in situ keratomileusis. Issue 9 (September 2015)
- Record Type:
- Journal Article
- Title:
- Comparison of ocular aberrations measured by a Fourier‐based Hartmann‐Shack and Zernike‐based Tscherning aberrometer before and after laser in situ keratomileusis. Issue 9 (September 2015)
- Main Title:
- Comparison of ocular aberrations measured by a Fourier‐based Hartmann‐Shack and Zernike‐based Tscherning aberrometer before and after laser in situ keratomileusis
- Authors:
- Sáles, Christopher S.
Manche, Edward E. - Abstract:
- Abstract : Purpose : To assess agreement between a Hartmann‐Shack aberrometer (Wavescan) and a Tscherning aberrometer (Wavelight Allegro Analyzer) and their respective agreement with manifest refraction before and after laser in situ keratomileusis (LASIK). Setting : Stanford Eye Laser Center, California, USA. Design : Prospective comparative observational study. Methods : Multiple readings were obtained both aberrometers preoperatively and 12 months after wavefront‐guided LASIK. Sphere, cylinder, spherical equivalent (SE), defocus Z(2, 0), astigmatism Z(2, 2), spherical aberration Z(4, 0), coma Z(3, 1), trefoil Z(3, 3), and total higher‐order aberrations (HOAs) were compared using intraclass correlation coefficients (ICCs) (perfect agreement = 1; disagreement = 0). Results : In the 100 study eyes, preoperative agreement was good to excellent between the aberrometers for the parameters of defocus, astigmatism, and spherical aberration (ICC: 0.8, 0.9, and 0.7, respectively) but was poor for coma, trefoil, and total HOAs (ICC: 0.6, –0.2, and 0.4, respectively). At 12 months, ICCs worsened for all parameters (ICC: defocus = 0.6; astigmatism = 0.2; spherical aberration = 0.6; coma = 0.4; trefoil = –0.3; total HOAs = 0.4). Preoperative agreement of sphere, cylinder, and SE was good to excellent between the manifest refraction and both aberrometers (ICC Hartmann‐Shack: 0.98, 0.95, and 0.97, respectively; ICC Tscherning: 0.97, 0.92, and 0.98, respectively). However, agreement wasAbstract : Purpose : To assess agreement between a Hartmann‐Shack aberrometer (Wavescan) and a Tscherning aberrometer (Wavelight Allegro Analyzer) and their respective agreement with manifest refraction before and after laser in situ keratomileusis (LASIK). Setting : Stanford Eye Laser Center, California, USA. Design : Prospective comparative observational study. Methods : Multiple readings were obtained both aberrometers preoperatively and 12 months after wavefront‐guided LASIK. Sphere, cylinder, spherical equivalent (SE), defocus Z(2, 0), astigmatism Z(2, 2), spherical aberration Z(4, 0), coma Z(3, 1), trefoil Z(3, 3), and total higher‐order aberrations (HOAs) were compared using intraclass correlation coefficients (ICCs) (perfect agreement = 1; disagreement = 0). Results : In the 100 study eyes, preoperative agreement was good to excellent between the aberrometers for the parameters of defocus, astigmatism, and spherical aberration (ICC: 0.8, 0.9, and 0.7, respectively) but was poor for coma, trefoil, and total HOAs (ICC: 0.6, –0.2, and 0.4, respectively). At 12 months, ICCs worsened for all parameters (ICC: defocus = 0.6; astigmatism = 0.2; spherical aberration = 0.6; coma = 0.4; trefoil = –0.3; total HOAs = 0.4). Preoperative agreement of sphere, cylinder, and SE was good to excellent between the manifest refraction and both aberrometers (ICC Hartmann‐Shack: 0.98, 0.95, and 0.97, respectively; ICC Tscherning: 0.97, 0.92, and 0.98, respectively). However, agreement was poor to fair between the manifest refraction and both aberrometers at 12 months (ICC Hartmann‐Shack: 0.4, 0.1, and 0.4, respectively; ICC Tscherning: 0.03, 0.02, and 0.2, respectively). Conclusions : Although some HOAs measured with both aberrometers agreed preoperatively, such agreement might not persist after LASIK. Spherocylinder measurements with both aberrometers seemed to agree closely with the manifest refraction before LASIK, but not at 12 months. Financial Disclosure : Dr. Manche has equity in Calhoun Vision, Inc., Krypton Vision, Seros Medical, LLC, and Veralas and is a consultant to Best Doctors, Gerson Lehrman Group. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 41:Issue 9(2015)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 41:Issue 9(2015)
- Issue Display:
- Volume 41, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 41
- Issue:
- 9
- Issue Sort Value:
- 2015-0041-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-09
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2015.09.014 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16665.xml