Anterior chamber depth studies. Issue 9 (September 2015)
- Record Type:
- Journal Article
- Title:
- Anterior chamber depth studies. Issue 9 (September 2015)
- Main Title:
- Anterior chamber depth studies
- Authors:
- Hoffer, Kenneth J.
Savini, Giacomo - Abstract:
- Abstract : Purpose : To compare the anterior chamber depth (ACD; corneal epithelium to lens) using 3 modalities and compare the change 1 day and 3 months postoperatively. Setting : Private practice, Santa Monica, California, USA. Design : Nonrandomized prospective series. Methods : The mean optical pachymetry and immersion ultrasound (US) of the ACD and partial coherence interferometry (PCI) were measured. Optical pachymetry ACD was measured in 675 eyes postoperatively at 1 day and 3 months. Results : The optical pachymetry ACD in 492 eyes was 3.17 mm ± 0.42 (SD); by immersion US, it was 2.99 ± 0.51 mm (0.18 mm deeper; P < .0001). In 178 eyes, the optical pachymetry ACD was 3.23 ± 0.45 mm; the PCI was 3.19 ± 0.48 mm (0.04 mm deeper), which was not statistically different ( P > .05). In 675 eyes, optical pachymetry ACD preoperatively was 3.19 ± 0.40 mm. The postoperative 1‐day optical pachymetry ACD was 4.35 ± 0.35 mm with a mean refractive error of −0.30 diopter (D); the final 3‐month optical pachymetry ACD was 4.47 ± 0.31 mm, with a mean refractive error of −0.07 D ( P < .0001). This is a mean intraocular lens (IOL) position shift of +0.12 mm posteriorly; the +0.23 D change represents a ratio of 1.92 D/mm of IOL axial movement. Conclusions : The PCI ACD was comparable with optical pachymetry, but careful immersion US led to a 0.18 mm shorter ACD reading that cannot be corrected by sound velocity. The posterior capsule contracted and moved the IOL posteriorly 0.12 mm,Abstract : Purpose : To compare the anterior chamber depth (ACD; corneal epithelium to lens) using 3 modalities and compare the change 1 day and 3 months postoperatively. Setting : Private practice, Santa Monica, California, USA. Design : Nonrandomized prospective series. Methods : The mean optical pachymetry and immersion ultrasound (US) of the ACD and partial coherence interferometry (PCI) were measured. Optical pachymetry ACD was measured in 675 eyes postoperatively at 1 day and 3 months. Results : The optical pachymetry ACD in 492 eyes was 3.17 mm ± 0.42 (SD); by immersion US, it was 2.99 ± 0.51 mm (0.18 mm deeper; P < .0001). In 178 eyes, the optical pachymetry ACD was 3.23 ± 0.45 mm; the PCI was 3.19 ± 0.48 mm (0.04 mm deeper), which was not statistically different ( P > .05). In 675 eyes, optical pachymetry ACD preoperatively was 3.19 ± 0.40 mm. The postoperative 1‐day optical pachymetry ACD was 4.35 ± 0.35 mm with a mean refractive error of −0.30 diopter (D); the final 3‐month optical pachymetry ACD was 4.47 ± 0.31 mm, with a mean refractive error of −0.07 D ( P < .0001). This is a mean intraocular lens (IOL) position shift of +0.12 mm posteriorly; the +0.23 D change represents a ratio of 1.92 D/mm of IOL axial movement. Conclusions : The PCI ACD was comparable with optical pachymetry, but careful immersion US led to a 0.18 mm shorter ACD reading that cannot be corrected by sound velocity. The posterior capsule contracted and moved the IOL posteriorly 0.12 mm, resulting in 0.23 D hyperopic shift. Financial Disclosure : Dr. Hoffer owns the registered trademark name "Hoffer ® " and receives royalties for its commercial use from Alcon Laboratories, Inc., Appasamy Associates, Carl Zeiss Meditec AG, DGH Technology, Inc., Ellex iScience, Inc., Haag‐Streit AG, Nidek Co., Ltd., Tomey Corp., Topcon Medical Systems, Inc., and Ziemer USA, Inc., as well as royalties from Slack, Inc. for the textbook IOL Power . Neither author has a financial or proprietary interest in any material or method mentioned. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 41:Issue 9(2015)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 41:Issue 9(2015)
- Issue Display:
- Volume 41, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 41
- Issue:
- 9
- Issue Sort Value:
- 2015-0041-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-09
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2015.10.010 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16665.xml